• Key Features & Attributes
  • Ratings & Reviews
  • Know your Supplier
  • Product description from supplier

LIEBERT GXT MT CX 2 kVA (LB)

Inclusive of all taxes

The LIEBERT GXT MT CX 2 kVA UPS (LB) from Shakti Power Solutions Pvt Limited is a premium online double-conversion uninterruptible power supply designed to ensure continuous and reliable power for critical IT infrastructure. This rack-mounted UPS unit, part of the esteemed Delta Amplon RT Series, provides a true sine wave output with a power factor of 0.9 and an impressive efficiency of up to 90%, ensuring energy savings while protecting your sensitive devices. Operating within an input voltage range of 175 to 280 Vac at full load and 120 to 175 Vac at partial load, this UPS can handle varying power conditions without compromising performance. Its compact dimensions (440 x 432 x 89 mm) and lightweight design (18 kg) make it ideal for scalable deployment in server rooms and telecom setups. With noise levels below 40 dB and operating tolerances for relative humidity from 5% to 95% (non-condensing), it ensures a quiet and durable operation environment. For extended backup requirements, the system supports optional external battery packs, making it suitable for networks, servers, VoIP systems, and telecommunications where uninterrupted power is paramount. Made in India and readily available with a MOQ of 1 unit, this UPS represents a reliable power safeguarding solution for business-critical applications.

Key Features

Features Description
UPS Type Online Double-Conversion
Capacity 2 kVA
Input Voltage Range 175 ~ 280 Vac (full load); 120 ~ 175 Vac (70~100% load)
Output Voltage Options 200 / 208 / 220 / 230 / 240 Vac
Output Power Factor 0.9
Efficiency Up to 90%
Form Factor Rack Mounted
Noise Level < 40 dB
Weight 18 kg
Dimensions (W x D x H) 440 x 432 x 89 mm
Relative Humidity Tolerance 5% to 95% (non-condensing)
External Battery Support Optional external battery pack for extended backup
Country of Origin Made in India
Attributes Description
Brand Delta
Model Name/Number Delta UPS Amplon Family - RT Series
Capacity 2 kVA
Input Voltage 175 ~ 280 Vac (full load); 120 ~ 175 Vac (70~100% load)
Output Voltage 200 / 208 / 220 / 230 / 240 Vac
Output Power Factor 0.9
Efficiency Up to 90%
Form Factor Rack Mounted
Noise Level < 40 dB
Weight 18 kg
Dimensions (W x D x H) 440 x 432 x 89 mm
Relative Humidity 5% ~ 95% (non-condensing)
Country of Origin Made in India
Availability In Stock
MOQ 1 Unit

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

Yes, this UPS supports connection to optional external battery packs which enable longer backup durations for critical applications.

The UPS operates quietly with noise levels below 40 dB, making it suitable for installation in office and telecom environments.

Yes, it provides consistent sine wave output and high efficiency, making it ideal for powering telecom systems.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Brand: shakti power solutions

Country Of Origin: India

LIEBERT GXT MT CX 2 kVA UPS – Rack-mount Internal Battery

LIEBERT GXT MT CX 2 kVA is a single-phase online double-conversion UPS module specifically engineered for 19-inch IT racks and localized telecom cabinets. utilizes a low-profile chassis with an integrated internal battery bank to provide continuous regulated power for small server arrays and network appliances. The unit architecture features a high-frequency inverter to minimize footprint while providing tight voltage regulation against mains disturbances. Offered in contract supply quantities, units ship in reinforced cartons with moisture-barrier film and serialized test reports. Supply-readiness is managed through factory-verified regulation purity and battery capacity checks, addressing the requirements of enterprise IT operators seeking documented reliability for multi-site campus rollouts requiring site-ready energy assets with traceable quality logs for institutional asset registration.

Key Features

  • Rack-mount compact form factor → specifically designed to integrate into standard 19-inch cabinets with minimal RU footprint, maximizing equipment density in technical closets.
  • Integrated sealed energy storage → features internal battery modules with replaceable trays to provide localized backup without the requirement for external battery enclosures.
  • Network telemetry suite → provides real-time monitoring via RS-232/USB and optional SNMP cards to facilitate centralized alarm reporting and graceful system shutdowns.

Technical Attributes

  • Rated Power: 2 kVA / 1.6 kW → primary selection parameter for matching localized IT rack and telecom equipment load profiles.
  • Mounting Standard: 19" Rack Compatible → selection parameter defining compatibility with existing data center cabinets and localized IT enclosures.
  • Battery Chemistry: Sealed VRLA → ensures safe, maintenance-free operation in unconditioned environments and identifies the lifecycle requirements.
  • Communications: Local LCD + Digital Interface → ensures compatibility with modern facility asset management tools and remote SCADA platforms.

LIEBERT GXT MT CX 2 kVA UPS — Rack-mounted Internal Battery Logic

The technical framework of the LIEBERT GXT MT CX 2 kVA UPS utilize a modular 19-inch chassis where the power stage and energy storage modules are integrated into a single high-stiffness enclosure. The structural reasoning for the internal battery trays is to provide "safe-state serviceability"—technicians can replace the battery trays from the front panel while the unit remains pressurized and online. measurement physics rely on high-fidelity current sensors that monitor the output regulation within ±2% accuracy. A failure in the inverter feedback loop—due to localized EMI—leads to "output distortion," manifesting as erratic behavior in connected diagnostic hardware—a failure mode that decommissions the accuracy of localized monitoring. quality consistency is managed through serialized test reports documenting voltage regulation within ±1% across the entire input range. The internal layout utilize conduction-cooled heatsinks and filtered airflow paths to stabilize component temperatures in dense equipment racks, ensuring the UPS serves as a stable energy asset for the facility operator.

Functional Performance and Operational Efficiency in IT Cabinets

Operational efficiency is achieved through the system’s high-efficiency conversion stages, which deliver peak efficiency even at partial loads, an essential operational standard for enclosed rack environments. functional performance centers on the unit’s support for continuous operation; if the unit detects a mains sag through its monitoring interface, it triggers an instantaneous battery transition. In a real operational scenario, a failure in the charging circuit—due to localized surge damage—leads to "battery starvation," where the energy storage remains uncharged despite mains availability—effectively decommissioning the backup node. To mitigate this, the unit features real-time charging status alarms. if the unit detects a battery end-of-life condition through its automated discharge monitoring, it provides a preemptive maintenance alert via its digital interface. thermal management of the control electronics is critical; the unit features heat-shielded enclosures to protect the ADCs from the high temperatures of unconditioned equipment closets. By providing a clean and deterministic signal for power status, the enclosure improves the situational awareness of the facility team, reducing the need for manual inspections.

Institutional Deployment and Logistical Readiness for Campus rollouts

Designed for small IT closets, point-of-sale servers, and retail telecom gear, the GXT MT CX is configured for the logistical requirements of project-scale multi-unit rollouts. Units ship in reinforced cartons with moisture-barrier film and anti-static foam inserts to protect the sensitive internal inductors and electrodes during transit. Failure to implement finish-protected packaging results in "terminal pitting," manifesting as intermittent power loss upon site commissioning. For international procurement, supply-readiness is supported through serialized test records and compliance declarations (ISO/CE). Export-ready documentation include unit configuration snapshots and installation checklists provided with each shipment to facilitate institutional asset registration. Packaging utilize humidity-control liners to prevent oxidation of the Gold-plated communication terminals. OEM branding and private-label firmware options are available under contract, allowing integrators to deliver branded suites with serialized records. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global manufacturing markets.

Frequently Asked Questions

  • What mounting depth is required for a standard rack? Depth and rail clearance are listed on the mechanical datasheet; universal rack kits are provided for standard 19-inch mounting.
  • Can the battery be replaced without shutting down the load? Yes; the unit features front-access removable battery trays designed for "hot-swap" service while the UPS is protected by the bypass or inverter.
  • Does the unit support remote SNMP monitoring? Yes; a dedicated slot is provided for optional network cards to facilitate centralized DCIM integration.
  • What documentation accompanies each lot? Shipments include serialized factory test reports, wiring diagrams, and commissioning checklists.
  • How is moisture risk managed during maritime transit? Packaging includes moisture-barrier liners and desiccant pouches inside a reinforced outer crate.


Electrical Equipment And Supplies

Uninterruptible Power Supply (ups)

shakti power solutions

LIEBERT GXT MT CX 2 KVA

Online Double-Conversion UPS

Rack Mounted UPS

Delta Amplon RT Series

2 KVA UPS India

IT Backup Power

Telecom UPS

Energy Efficient UPS

LIEBERT GXT MT CX 2 kVA (LB)

Inclusive of all taxes

You Save: 0

Send Inquiry
shakti power solutions pvt limited

Amritsar , India

Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler

GST- 03abgcs0227d1zz

  • Secure
    Transaction

  • Day
    Dispatch

Report a problem with this product