Delta UPS N Series, Single Phase 6/10 kVA

Inclusive of all taxes

The Delta UPS N Series Single Phase 6/10 kVA is designed for industrial applications requiring reliable power backup and protection. Featuring true online double conversion technology and an IGBT-based rectifier, this UPS ensures a stable and clean power supply with minimal downtime. The unit supports a wide input voltage range from 110VAC to 275VAC and provides long battery backup via an external battery pack. The UPS has a compact and efficient design with rack and tower convertible options, making it ideal for various deployment environments. Equipped with an advanced graphical LCD display, operators can easily monitor UPS performance and status. With robust overvoltage protection and a power dense footprint of only 2U height, the Delta UPS N Series enhances operational uptime and protects sensitive industrial equipment from power disturbances. The product is lightweight at 15 kg and dimensioned at 438 x 86.2 x 573 mm, facilitating easy installation in existing infrastructure setups.

Key Features

Features Description
Power Capacity 6/10 kVA
Input Voltage Range 110VAC - 275VAC
Phase Single Phase In / Single Phase Out
Battery Type Long backup external battery
UPS Technology IGBT based rectifier, True Online Double Conversion
Display New Graphical LCD Display
Form Factor Rack & Tower Convertible, 2U Height
Protection Feature Overvoltage Protection
Weight 15 kg
Dimensions (WxHxD) 438 x 86.2 x 573 mm
Availability In Stock
Attributes Description
Brand Eaton
Model Number DXRT-10KVA
Usage Industrial Applications
Battery Backup Long backup external battery
Input Phase Single Phase
Output Phase Single Phase
Protection Type Overvoltage Protection
Weight 15 kg
Dimensions 438 x 86.2 x 573 mm
Input Voltage Range 110VAC - 275VAC
UPS Topology True Online Double Conversion
Rectifier Type IGBT Based
Display Type Graphical LCD
Form Factor Rack & Tower Convertible
Power Density 2U Height

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

The UPS supports a wide input voltage range of 110VAC to 275VAC ensuring stable operation under fluctuating power conditions.

Yes, the UPS is designed to be rack and tower convertible with a compact 2U height form factor for flexible installation.

It uses a long backup external battery system, providing extended runtime during power outages.

The UPS employs an IGBT-based rectifier with True Online Double Conversion topology for clean and stable power output.

Yes, it includes overvoltage protection to safeguard connected equipment from power surges.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Brand: shakti power solutions

Country Of Origin: India

Delta N Series Single Phase 6/10 kVA UPS – Online Power Module

Delta UPS N Series 6/10 kVA is an online double-conversion power module specifically engineered for localized critical protection in equipment closets and edge IT racks. Utilizing high-frequency conversion and an integrated battery management system (BMS), the unit provides stable AC output with zero transfer time. The architecture features a compact footprint suitable for rack or tower deployment, delivering 6 kVA or 10 kVA output with ±2% regulation. Units are supplied with serialized testing records and packaged with humidity-control measures for international distribution. Supply-readiness is managed through factory-verified output fidelity and full-load burn-in, addressing the requirements of wholesale distribution channels seeking documented reliability for institutional asset management and site acceptance testing. Packaging utilize anti-static separators and moisture-barrier liners for multimodal transport security.

Key Features

  • Double-conversion high-frequency topology → ensures complete isolation of the load from mains disturbances, providing a pure sine-wave output and consistent frequency regulation for sensitive electronics.
  • Integrated BMS monitoring → features real-time tracking of cell voltage and temperature to provide battery state-of-health (SoH) metrics for lifecycle planning.
  • Compact rack/tower form factor → provides mechanical flexibility for installation in standard equipment closets or as a standalone tower in constrained utility technical spaces.

Technical Attributes

  • Power Ratings: 6 / 10 kVA Selectable → primary selection parameter for matching centralized server clusters or high-load telecom circuits.
  • Output Stability: ±2% Regulation → essential parameter for maintaining the stability of high-frequency diagnostic and IT hardware.
  • Efficiency Rating: ≥92% at Nominal Load → selection parameter for ensuring low heat draw and reduced power waste in small equipment rooms.
  • Monitoring: SNMP Remote Management → determines the ability to integrate with centralized SCADA and facility-wide alarm aggregation platforms.

N Series 6/10 kVA – Architecture and Manufacturing Logic

The technical framework of the Delta UPS N Series, Single Phase 6/10 kVA houses the rectifier, inverter, and battery charger within a high-stiffness metallic enclosure featuring segregated airflow channels. The structural reasoning for the dual-path ventilation is to maintain component temperature stability by isolating the power inductors from the microprocessor logic. measurement physics rely on high-fidelity sensors that monitor both input voltage and DC bus stability. A failure in the voltage regulation circuit—due to localized EMI—leads to "waveform clipping," manifesting as erratic behavior in connected diagnostic hardware—a failure mode that decommissions the accuracy of localized monitoring. Quality consistency is managed through serialized test reports documenting regulation purity and efficiency. The internal PCBA is conformal-coated to prevent moisture-induced tracking in unconditioned utility closets. Internal cable routing utilizes high-grade strain-relief points to prevent "connection fatigue" during field maintenance events, ensuring the unit serves as a stable energy asset for the facility operator.

Functional Performance and Operational Efficiency in Small Rooms

Operational efficiency is achieved through the unit’s high-efficiency conversion stages, which deliver peak efficiency above 92%, an essential operational standard for small data halls where heat management is critical. functional performance centers on the unit’s environmental stability; if the unit detects a fan motor failure through its monitoring interface, it triggers a diagnostic alarm and initiates a fail-safe mode. In a real operational scenario, a failure in the charging circuit—due to internal firmware corruption—leads to "electrolyte dry-out," which results in a sudden loss of backup minutes during a utility failure—effectively decommissioning the facility protection node. The N Series utilize intelligent multi-stage charging to mitigate this risk. if the unit detects a loss of signal gain—indicating an internal sensor fault—it triggers an alarm via its digital interface, allowing for event-driven replacement. By providing a clean and deterministic signal for power status, the enclosure improves the situational awareness of the facility team, ensuring that thermal and electrical thresholds are accurately tracked for institutional maintenance audits.

Institutional Deployment and Logistical Readiness for Export Processes

Designed for telecommunications closets, retail IT hubs, and medical device backup, the N Series is configured for the logistical requirements of project-scale multi-site procurement. Units ship in reinforced cartons with moisture-barrier film and anti-static foam inserts to protect the sensitive internal inductors and electrodes during transit. Failure to implement finish-protected packaging results in "terminal pitting," manifesting as intermittent power loss upon site commissioning. For international procurement, supply-readiness is supported through lot-specific test certificates and material declarations (ISO/CE). Export-ready documentation include unit configuration snapshots and certificates of conformity provided with each lot to facilitate institutional asset registration. Packaging utilize humidity-control liners and desiccant to prevent oxidation of the Gold-plated terminals during transport. OEM branding and private-label firmware options are available under contract, providing system integrators with verified hardware that meet the safety and performance requirements of global manufactured utility markets.

Frequently Asked Questions

  • What is the recommended storage temperature? Store units between 10–30°C in low-humidity areas; batteries should be periodically charged to maintain capacity.
  • How is the unit protected from moisture in the field? PCBs are conformally coated and enclosures feature gasketed seals with IP20 standard protection for indoor technical rooms.
  • What documentation is provided for site acceptance? Consignments include serialized test certificates, battery discharge profiles, and quality inspection reports.
  • Can the unit handle high-density server racks? Yes; the 10 kVA model is specifically rated for high-load IT applications in standard 19-inch racks.
  • What increases repair time on-site? Keyed connectors and front-access modular components are used to reduce mean time to repair (MTTR).


Electrical Equipment And Supplies

Uninterruptible Power Supply (ups)

shakti power solutions

Delta UPS N Series

6 KVA UPS

10 KVA UPS

Single Phase UPS

True Online UPS

Industrial UPS Backup

IGBT UPS

Long Backup UPS

Rack Tower UPS

Delta UPS N Series, Single Phase 6/10 kVA

Inclusive of all taxes

You Save: 0

Send Inquiry
shakti power solutions pvt limited

Amritsar , India

Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler

GST- 03abgcs0227d1zz

  • Secure
    Transaction

  • Day
    Dispatch

Report a problem with this product