• Key Features & Attributes
  • Ratings & Reviews
  • Know your Supplier
  • Product description from supplier

VERTIV Liebert ITA2 6 kVA

Inclusive of all taxes

The VERTIV Liebert ITA2 6 kVA UPS is a high-performance, double conversion online uninterruptible power supply designed specifically for critical IT infrastructure requiring reliable and consistent power protection. Delivering a capacity of 6 kVA, this UPS ensures total isolation between the load and the mains, safeguarding sensitive equipment from power surges, fluctuations, and interruptions. Ideal for data centers, telecommunications, VOIP applications, and mission-critical environments such as banking and financial institutions, the Liebert ITA2 provides stable single-phase output power from a three-phase input source. This unit features an advanced monitoring display showing UPS status, load level, battery status, input/output voltages, discharge timer, and fault conditions for proactive system management. With over 92% efficiency and a compact tower form factor operating quietly below 58 dB, this UPS facilitates seamless integration into space-constrained environments. The hot standby support enhances system reliability during maintenance or unexpected failures, ensuring uninterrupted power delivery to safeguard sensitive equipment at all times.

Key Features

Features Description
Capacity 6 kVA
Topology True Double Conversion Online UPS
Input Voltage 305-478 VAC (3-phase) @ 100% load
Output Voltage 208 / 220 / 230 / 240 VAC (Single phase)
Efficiency >92%
Form Factor Tower model
Audible Noise <58 dB at 1 meter
Display UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, Fault conditions
Weight 28 kg
Isolation Total load isolation from mains
Support Hot standby configuration for critical applications
Attributes Description
Brand Vertiv
Model Liebert ITA2 6 kVA
Capacity 6000 VA / 5400 W
Input Voltage Range 305-478 VAC (3-phase)
Output Voltage Options 208 / 220 / 230 / 240 VAC (Single phase)
Output Configuration 3 Phase IN - 1 Phase OUT
Efficiency >92%
Noise Level < 58 dB at 1 meter
Dimensions (WxDxH) 592 x 250 x 576 mm
Weight 28 kg
Form Factor Tower
Display Type LED indicators for UPS status, Load level, Battery status, Voltages, Discharge timer, Fault alerts
Application Data networks, Small data centers, VOIP, Banks, and other critical IT infrastructure
Availability In Stock

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

Yes, the VERTIV Liebert ITA2 6 kVA supports hot standby configuration, allowing seamless backup power integration for critical applications.

It supports a three-phase input voltage range of 305-478 VAC at 100% load, ensuring compatibility with a wide range of industrial power supplies.

Yes, this UPS provides total isolation between the load and the mains by isolating both input and output sections, enhancing power quality and equipment protection.

The output voltage can be configured to 208, 220, 230, or 240 VAC single-phase to suit various equipment requirements.

This UPS operates quietly with an audible noise level below 58 dB measured at 1 meter, suitable for office and data center environments.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Brand: shakti power solutions

Country Of Origin: India

ITA2 6 kVA UPS System – Tower Online UPS

ITA2 6 kVA UPS System is a compact single-phase online uninterruptible power supply designed for light industrial and small data room deployments. Utilizing synchronous rectification and microprocessor control, the unit maintain regulated ±1% output regulation across wide input variations. The compact tower footprint is engineered for floor or shelf installation in clinical equipment areas and IT closets where space is a selection parameter. Units are prepared for industrial distribution with sequential serial tracking and consolidated packing, including vapor-barrier wraps for extended storage. Production lots include performance test logs and electrical safety declarations, ensuring supply-readiness for contract purchasing and institutional maintenance planning. This power module is essential for facilities requiring high-frequency regulation and surge-tolerant backup for sensitive diagnostic and networking hardware.

Key Features

  • True online double-conversion → ensures continuous voltage and frequency regulation to protect loads from mains disturbances and spikes.
  • Compact tower form factor → minimizes floor space requirements and facilitates installation in confined technical closets or medical cabinets.
  • Intelligent multi-stage charging → reduces battery overcharge cycles and execute temperature compensation to extend the serviceable life of the battery pack.

Technical Attributes

  • Rated Capacity: 6 kVA → selection parameter for matching active loads up to 5.4 kW with headroom for inrush currents.
  • Bypass Topology: Static bypass with manual transfer → supports safe maintenance operations without interrupting load continuity.
  • Operating Range: Industrial ambient profile → maintains performance in controlled plant rooms up to 40°C.
  • Communications: SNMP, RS-232, USB → selection for integration with facility monitoring and asset management systems.

Internal Conversion Architecture and Thermal Design of the ITA2 6 kVA UPS

The technical framework of the VERTIV Liebert ITA2 6 kVA UPS System utilize a high-frequency double-conversion topology where the input AC is converted to DC and then synthesized into a clean AC sine wave. This architecture ensures that the load is isolated from common-mode noise and frequency shifts—a failure to maintain this isolation results in "clock drift" and processor errors in sensitive medical diagnostic gear. The internal build separates the power modules from the control electronics into discrete compartments to optimize thermal flow. High-performance IGBT stacks are cooled via dedicated variable-speed fans that modulate based on real-time heatsink temperature monitoring. If the fan system fails, the microprocessor triggers a thermal derating sequence to prevent the localized overheating that frequently destroys DC-link capacitors. Printed circuit assemblies are conformally coated to resist moisture-induced tracking, a critical standard for units stored in unconditioned regional warehouses. Quality consistency is managed through serialized performance test logs that record the unit's regulation accuracy and THD profile under 0% to 100% load variations, ensuring the UPS serves as a durable infrastructure component.

Operational Dynamics and Battery Lifecycle Management in Compact Online Units

Operational efficiency is enhanced through the use of synchronous rectification, which reduces internal heat losses and improves the overall conversion ratio compared to legacy analog designs. Functional performance centers on the unit’s ability to handle surge-tolerant loads typical of medical equipment. The integrated charger management system executes an adaptive multi-stage charging algorithm; failure to implement this results in electrolyte stratification and premature capacity fade in the battery modules. The UPS chassis supports the mounting of external battery packs via a standardized high-current connector, allowing B2B facility managers to scale runtime without full unit decommissioning. In the event of an internal inverter fault, the static bypass executes a transfer in under 4 milliseconds, ensuring continuity for loads that would otherwise crash during a mains interruption. Integrated telemetry provides event logging and state-of-charge (SoC) metrics, allowing for predictive maintenance scheduling. This systematic approach ensure that the UPS remains ready for emergency transitions, providing the data necessary for institutional asset management and lifecycle accounting in clinical and light industrial environments.

Institutional Deployment and Logistical Readiness for Regional Rollouts

Designed for medical clinics, small IT closets, and industrial control frames, the ITA2 6 kVA is configured for the logistical requirements of institutional procurement. Units are packed in shock-rated crates with internal bracing to protect the sensitive inverter alignment and transformer mounts from multimodal transit damage. Failure to implement shock-rated packaging can lead to microscopic fractures in the PCBA solder joints, resulting in intermittent power faults months after installation. For international projects, supply-readiness is supported through sequential serial tracking and lot-based electrical safety declarations. Export-ready documentation include unit configuration snapshots and environment manifests provided with each shipment. Packaging utilize vapor-barrier liners and moisture-absorbing media to prevent humidity-induced terminal oxidation during transit. OEM options permit customized front bezels and load management profiles for private-label deployments. This high-authority approach ensures that procurement teams receive verified, site-ready hardware that meet the technical performance and safety requirements of global markets (CE/IEC). Every delivery is accompanied by a commissioning guide and terminal pinout diagrams, providing the technical depth required for asset onboarding and rapid site integration.

Frequently Asked Questions

  • Can the unit be expanded for longer runtime? Yes, the chassis features a standardized connector for adding external extended-runtime battery packs.
  • What is the recommended storage interval? Batteries should be reconditioned after 6–9 months of storage to prevent capacity loss from self-discharge.
  • How is moisture migration mitigated? Internal PCBA components feature conformal coating to protect against moisture-induced tracking.
  • What evidence of quality is provided? Each lot includes serialized electrical test logs and factory inspection certificates to support procurement.


Electrical Equipment And Supplies

Uninterruptible Power Supply (ups)

shakti power solutions

VERTIV Liebert ITA2 6 KVA

6 KVA UPS

Double Conversion UPS

3 Phase Input UPS

Single Phase Output UPS

Critical Power Protection UPS

Industrial UPS

Data Center UPS

VOIP UPS

VERTIV Liebert ITA2 6 kVA

Inclusive of all taxes

You Save: 0

Send Inquiry
shakti power solutions pvt limited

Amritsar , India

Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler

GST- 03abgcs0227d1zz

  • Secure
    Transaction

  • Day
    Dispatch

Report a problem with this product