• Key Features & Attributes
  • Ratings & Reviews
  • Know your Supplier
  • Product description from supplier

Delta UPS EH Series, Three Phase 10/15/20 kVA, For Industrial

Inclusive of all taxes

Delta UPS EH Series Three Phase 10/15/20 kVA is designed specifically for industrial applications requiring reliable and high-performance power backup. This tower-form factor UPS delivers true online double-conversion with fully rated power, ensuring maximum power availability without any derating. Featuring advanced three-level IGBT topology for both power factor correction and inverter sections, it achieves outstanding energy efficiency up to 96% AC-AC, reducing operational costs significantly. With input current total harmonic distortion below 3% and a high input power factor greater than 0.99, it optimizes power quality and reduces electrical disturbances in sensitive industrial environments. Compact and robust in design, weighing 86.06 kg and measuring 380 x 800 x 800 mm, it is engineered to safeguard mission-critical industrial operations by maintaining continuous, clean, and stable power supply. The Delta UPS EH Series is made in India and readily available through Shakti Power Solutions Pvt Limited with a minimum order quantity of 1 unit, ideal for businesses seeking efficient, cost-effective, and durable power protection solutions.

Key Features

Features Description
Power Capacity 10/15/20 kVA
Phase Configuration Three Phase Input - Three Phase Output
UPS Topology True Online Double-Conversion
Efficiency Up to 96% AC-AC Efficiency
Power Factor Input Power Factor > 0.99
Total Harmonic Distortion (THD) < 3% Input Current THD
Form Factor Tower
Dimensions (W x D x H) 380 x 800 x 800 mm
Weight 86.06 kg
Country of Origin Made in India
Availability In Stock
Ideal Application Industrial Mission Critical Operations
Attributes Description
Model Name/Number Delta UPS EH Series
Capacity Range 10 kVA, 15 kVA, 20 kVA
Configuration 3 Phase IN - 3 Phase OUT
UPS Type Online Double Conversion
Power Rating 10/15/20 kVA
Efficiency Up to 96%
Input Power Factor > 0.99
Total Harmonic Distortion (THD) < 3%
Form Factor Tower
Weight 86.06 kg
Dimensions (WxDxH) 380 x 800 x 800 mm
Country of Origin India
Availability In Stock

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

The Delta UPS EH Series offers up to 96% AC-AC efficiency, making it highly energy-efficient for industrial applications.

Yes, this UPS supports a three-phase input to three-phase output configuration, ideal for industrial power requirements.

The input current Total Harmonic Distortion (THD) is less than 3%, ensuring minimal electrical noise and stable power delivery, critical for sensitive industrial equipment.

Absolutely, this UPS is specifically designed for mission-critical applications, providing maximum power availability without derating.

The minimum order quantity is 1 unit, allowing businesses to purchase as per their individual operational needs.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Brand: shakti power solutions

Country Of Origin: India

Delta UPS EH Series 10/15/20 kVA – Three Phase Rack/Tower Module

Delta UPS EH Series 10/15/20 kVA is a compact, convertible rack/tower power module engineered for mid-load industrial and IT applications. Utilizing an online double-conversion topology, the unit delivers stable power with low harmonic distortion (<3%) and rapid transient response. The unit architecture features a modular control interface and front-access maintenance panels to minimize service duration and facility footprint. Units are available in rack-ready formats, shipping on palletized skids with moisture-barrier liners and serialized test certificates. Supply-readiness is managed through per-unit electrical verification and functional burn-in testing, addressing the requirements of facility managers seeking resilient, site-ready power protection for secondary data rooms and industrial control panels. Packaging utilize anti-static foam inserts and corner protection to preserve the integrity of the power semiconductors during multimodal transport.

Key Features

  • Convertible rack/tower architecture → provides mechanical flexibility for installation in standard 19-inch IT racks or as a standalone tower in constrained utility closets.
  • Embedded phase-balanced monitoring → features per-phase metering and load balancing diagnostics to facilitate optimized energy distribution across the facility grid.
  • Double-conversion online logic → ensures continuous filtering of mains disturbances, delivering a pure AC sine-wave output and seamless transitions to battery power.

Technical Attributes

  • Power Ratings: 10 / 15 / 20 kVA → selection parameter for matching the power profile of clustered server nodes or localized plant control circuits.
  • Output Quality: THD <3% (Linear) → essential parameter for maintaining the stability of sensitive diagnostic and microprocessor-based hardware.
  • Redundancy: Parallel up to 3 units → selection parameter defining the system’s ability to grow in resilience through N+1 parallel configurations.
  • Battery Strategy: Internal / External → determines the autonomy window and identifies the ventilation requirements for the localized equipment room.

EH Series – Construction and Component Layout Logic

The technical framework of the Delta UPS EH Series, Three Phase 10/15/20 kVA positions the rectifier, inverter, and control boards within a high-stiffness metallic enclosure with segregated airflow channels. The structural reasoning for this layout is to reduce "thermal stress" on the electrolytic capacitors; by directing cooled intake air over the heat-sensitive components before reaching the power inductors, the system extends the life of the DC bus filter. measurement physics rely on high-sampling-rate feedback loops that monitor both phase-to-neutral and phase-to-phase voltages. A failure in the phase-synchronization circuit—due to localized EMI—leads to "output jitter," manifesting as erratic timing in connected automated machinery. This failure mode decommissions the accuracy of localized process control. Quality consistency is managed through serialized test certificates documenting waveform purity under full-load steps. The power stage PCBs are conformal-coated to prevent moisture-induced tracking in unconditioned industrial rooms, a critical standard for maintaining high MTBF (Mean Time Between Failure).

Functional Performance and Operational Efficiency in Infrastructure

Operational efficiency is achieved through the unit’s high-frequency conversion stages, which deliver peak efficiency above 94% at typical load levels (50–75%). functional performance centers on the unit’s ability to handle inrush-heavy loads; the inverter utilizes fast current-mode control to limit the impact of downstream equipment starts on the overall system stability. In a real operational scenario, a failure in the charging logic—due to internal firmware corruption—leads to "overcharge heating," which can result in battery container swelling and localized fire hazards. The EH series utilizes integrated thermal sensors in the battery compartment to execute a protective charger shutdown if temperatures exceed safety thresholds. If the unit detects an internal logic fault, it triggers an audible alarm and provides a fault signal via the digital interface, allowing for event-driven maintenance before a total loss of load occur. By providing a clean and deterministic signal for power status, the unit improves the situational awareness of the facility management team, facilitating institutional maintenance audits.

Institutional Deployment and Logistical Readiness for Export Processes

Designed for industrial control panels, medical device backup, and branch data rooms, the EH Series is configured for the logistical requirements of multimodal procurement. Units ship in reinforced cartons on palletized skids with anti-static separators and moisture-barrier liners to protect the sensitive internal processors from environmental degradation during transit. Failure to implement shock-mitigating packaging can lead to "cracked solder joints" on the power modules, manifesting as intermittent faults weeks after site commissioning. For international procurement, supply-readiness is supported throughserialized test logs and compliance declarations (ISO/CE). Export-ready documentation include unit configuration snapshots and installation checklists provided with each shipment to facilitate institutional asset registration. Packaging utilize vapor-barrier covers and desiccants to prevent finish degradation during maritime freight. OEM branding and private-label firmware options are available under contract, allowing system integrators to deliver branded suites with serialized records. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global manufacturing and healthcare markets.

Frequently Asked Questions

  • Can the unit be converted between rack and tower modes in the field? Yes; the mechanical chassis and rotatable HMI display allow for field reconfiguration to match site mounting constraints.
  • What is the typical battery service life? Internal VRLA modules typically provide a 3-5 year service life; annual capacity testing is recommended to ensure standby readiness.
  • How many units can be paralleled? The architecture supports paralleling up to 3 units for either increased capacity or N+1 redundancy.
  • What documentation accompanies each unit? Every shipment include unit-specific FAT reports, electrical safety declarations, and a commissioning guide.
  • How is moisture risk managed in storage? Units ship in sealed moisture-barrier bags with desiccant; storage in climate-controlled areas below 30°C is recommended.


Electrical Equipment And Supplies

Uninterruptible Power Supply (ups)

shakti power solutions

Delta UPS EH Series

Three Phase UPS

10 KVA UPS

15 KVA UPS

20 KVA UPS

Online Double Conversion UPS

Industrial UPS India

High Efficiency UPS

Power Backup UPS

Delta UPS EH Series, Three Phase 10/15/20 kVA, For Industrial

Inclusive of all taxes

You Save: 0

Send Inquiry
shakti power solutions pvt limited

Amritsar , India

Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler

GST- 03abgcs0227d1zz

  • Secure
    Transaction

  • Day
    Dispatch

Report a problem with this product