Inclusive of all taxes
Delta UPS EH Series Three Phase 10/15/20 kVA is designed specifically for industrial applications requiring reliable and high-performance power backup. This tower-form factor UPS delivers true online double-conversion with fully rated power, ensuring maximum power availability without any derating. Featuring advanced three-level IGBT topology for both power factor correction and inverter sections, it achieves outstanding energy efficiency up to 96% AC-AC, reducing operational costs significantly. With input current total harmonic distortion below 3% and a high input power factor greater than 0.99, it optimizes power quality and reduces electrical disturbances in sensitive industrial environments. Compact and robust in design, weighing 86.06 kg and measuring 380 x 800 x 800 mm, it is engineered to safeguard mission-critical industrial operations by maintaining continuous, clean, and stable power supply. The Delta UPS EH Series is made in India and readily available through Shakti Power Solutions Pvt Limited with a minimum order quantity of 1 unit, ideal for businesses seeking efficient, cost-effective, and durable power protection solutions.
Key Features
| Features | Description |
|---|---|
| Power Capacity | 10/15/20 kVA |
| Phase Configuration | Three Phase Input - Three Phase Output |
| UPS Topology | True Online Double-Conversion |
| Efficiency | Up to 96% AC-AC Efficiency |
| Power Factor | Input Power Factor > 0.99 |
| Total Harmonic Distortion (THD) | < 3% Input Current THD |
| Form Factor | Tower |
| Dimensions (W x D x H) | 380 x 800 x 800 mm |
| Weight | 86.06 kg |
| Country of Origin | Made in India |
| Availability | In Stock |
| Ideal Application | Industrial Mission Critical Operations |
| Attributes | Description |
|---|---|
| Model Name/Number | Delta UPS EH Series |
| Capacity Range | 10 kVA, 15 kVA, 20 kVA |
| Configuration | 3 Phase IN - 3 Phase OUT |
| UPS Type | Online Double Conversion |
| Power Rating | 10/15/20 kVA |
| Efficiency | Up to 96% |
| Input Power Factor | > 0.99 |
| Total Harmonic Distortion (THD) | < 3% |
| Form Factor | Tower |
| Weight | 86.06 kg |
| Dimensions (WxDxH) | 380 x 800 x 800 mm |
| Country of Origin | India |
| Availability | In Stock |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
The Delta UPS EH Series offers up to 96% AC-AC efficiency, making it highly energy-efficient for industrial applications.
Yes, this UPS supports a three-phase input to three-phase output configuration, ideal for industrial power requirements.
The input current Total Harmonic Distortion (THD) is less than 3%, ensuring minimal electrical noise and stable power delivery, critical for sensitive industrial equipment.
Absolutely, this UPS is specifically designed for mission-critical applications, providing maximum power availability without derating.
The minimum order quantity is 1 unit, allowing businesses to purchase as per their individual operational needs.
Brand: shakti power solutions
Country Of Origin: India
Delta UPS EH Series 10/15/20 kVA is a compact, convertible rack/tower power module engineered for mid-load industrial and IT applications. Utilizing an online double-conversion topology, the unit delivers stable power with low harmonic distortion (<3%) and rapid transient response. The unit architecture features a modular control interface and front-access maintenance panels to minimize service duration and facility footprint. Units are available in rack-ready formats, shipping on palletized skids with moisture-barrier liners and serialized test certificates. Supply-readiness is managed through per-unit electrical verification and functional burn-in testing, addressing the requirements of facility managers seeking resilient, site-ready power protection for secondary data rooms and industrial control panels. Packaging utilize anti-static foam inserts and corner protection to preserve the integrity of the power semiconductors during multimodal transport.
The technical framework of the Delta UPS EH Series, Three Phase 10/15/20 kVA positions the rectifier, inverter, and control boards within a high-stiffness metallic enclosure with segregated airflow channels. The structural reasoning for this layout is to reduce "thermal stress" on the electrolytic capacitors; by directing cooled intake air over the heat-sensitive components before reaching the power inductors, the system extends the life of the DC bus filter. measurement physics rely on high-sampling-rate feedback loops that monitor both phase-to-neutral and phase-to-phase voltages. A failure in the phase-synchronization circuit—due to localized EMI—leads to "output jitter," manifesting as erratic timing in connected automated machinery. This failure mode decommissions the accuracy of localized process control. Quality consistency is managed through serialized test certificates documenting waveform purity under full-load steps. The power stage PCBs are conformal-coated to prevent moisture-induced tracking in unconditioned industrial rooms, a critical standard for maintaining high MTBF (Mean Time Between Failure).
Operational efficiency is achieved through the unit’s high-frequency conversion stages, which deliver peak efficiency above 94% at typical load levels (50–75%). functional performance centers on the unit’s ability to handle inrush-heavy loads; the inverter utilizes fast current-mode control to limit the impact of downstream equipment starts on the overall system stability. In a real operational scenario, a failure in the charging logic—due to internal firmware corruption—leads to "overcharge heating," which can result in battery container swelling and localized fire hazards. The EH series utilizes integrated thermal sensors in the battery compartment to execute a protective charger shutdown if temperatures exceed safety thresholds. If the unit detects an internal logic fault, it triggers an audible alarm and provides a fault signal via the digital interface, allowing for event-driven maintenance before a total loss of load occur. By providing a clean and deterministic signal for power status, the unit improves the situational awareness of the facility management team, facilitating institutional maintenance audits.
Designed for industrial control panels, medical device backup, and branch data rooms, the EH Series is configured for the logistical requirements of multimodal procurement. Units ship in reinforced cartons on palletized skids with anti-static separators and moisture-barrier liners to protect the sensitive internal processors from environmental degradation during transit. Failure to implement shock-mitigating packaging can lead to "cracked solder joints" on the power modules, manifesting as intermittent faults weeks after site commissioning. For international procurement, supply-readiness is supported throughserialized test logs and compliance declarations (ISO/CE). Export-ready documentation include unit configuration snapshots and installation checklists provided with each shipment to facilitate institutional asset registration. Packaging utilize vapor-barrier covers and desiccants to prevent finish degradation during maritime freight. OEM branding and private-label firmware options are available under contract, allowing system integrators to deliver branded suites with serialized records. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global manufacturing and healthcare markets.
Inclusive of all taxes
You Save: 0
Amritsar , India
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler
GST- 03abgcs0227d1zz