Inclusive of all taxes
The Delta UPS Amplon Family RT Series offers reliable and efficient uninterruptible power supply solutions ranging from 5 to 10 kVA for single phase and 10 to 20 kVA for three phase applications. Designed with advanced online double-conversion technology, these UPS units provide consistent sine-wave power output, protecting critical equipment from power disturbances and outages. With a compact footprint measuring 421 x 190 x 318 mm (W x D x H) and robust design suited for demanding environments, they ensure continuous power with high AC-AC efficiency of up to 91%, significantly reducing energy consumption and operational costs. Equipped with input power factor correction, the Amplon RT Series supports optimal power usage and enhanced grid compatibility. Made in India and available in stock with a minimum order quantity (MOQ) of 1, this series is an ideal choice for businesses seeking dependable and flexible power backup solutions with superior total cost of ownership and easy integration into various industrial and commercial setups.
Key Features
| Features | Description |
|---|---|
| Power Range | 5 to 10 kVA Single Phase, 10 to 20 kVA Three Phase |
| UPS Type | Online Double-Conversion |
| Output Waveform | Pure Sine Wave |
| Input Power Factor Correction | Yes |
| AC-AC Efficiency | Up to 91% |
| Dimensions (W x D x H) | 421 x 190 x 318 mm |
| Operating Humidity Range | 20% to 95% (non-condensing) |
| Power Rating | 1-2 kVA / 0.9-1.8 kW |
| Country of Origin | Made in India |
| Availability | In Stock |
| Minimum Order Quantity | 1 Unit |
| Attributes | Description |
|---|---|
| Model Series | Delta UPS Amplon RT Series |
| Input Voltage | Single and Three Phase Options |
| Output Voltage | Stable Sine Wave Output |
| Technology | Online Double Conversion |
| Efficiency | Up to 91% AC-AC |
| Dimensions (W x D x H) | 421 x 190 x 318 mm |
| Humidity Range | 20% to 95% (Non-Condensing) |
| Power Rating kVA | 5 to 10 kVA Single Phase, 10 to 20 kVA Three Phase |
| Power Rating kW | 1kVA/0.9kW to 2kVA/1.8kW |
| Input Power Factor | Corrected |
| Origin | Made in India |
| Stock Status | Available |
| MOQ | 1 Unit |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
The series supports both single phase power from 5 to 10 kVA and three phase power from 10 to 20 kVA configurations.
The UPS offers an AC-AC efficiency of up to 91%, enabling energy savings during power conversion.
Yes, it operates efficiently within a relative humidity range of 20% to 95% non-condensing.
The UPS utilizes online double-conversion technology to provide stable and clean sine-wave output.
Shakti Power Solutions Pvt Limited allows a minimum order quantity of 1 unit.
Brand: shakti power solutions
Country Of Origin: India
Delta Amplon RT Series is a versatile power protection platform covering 5–10 kVA single-phase and 10–20 kVA three-phase requirements. Utilizing a convertible rack/tower chassis, the unit architecture adapts to diverse facility layouts without hardware replacement. The design features high-density power stages and integrated network management for centralized oversight. Supplied in palletized cases for project-scale procurement, units ship with serialized test certificates and functional burn-in logs. Supply-readiness is managed through per-unit voltage regulation checks, addressing the requirements of IT managers and industrial integrators seeking documented reliability for localized equipment clusters requiring scalable runtime and institutional asset registration. Packaging includes anti-shock inserts for secure multimodal transport.
The technical framework of the Delta UPS Amplon Family RT Series utilize a common high-frequency power electronics platform engineered for high power density. The structural reasoning for the convertible chassis is to provide "inventory versatility"—facility managers can standardize on a single model for both rack and tower installations. measurement physics rely on high-speed feedback loops that coordinate the IGBT (Insulated-Gate Bipolar Transistor) switching at kHz frequencies to synthesize a pure AC sine wave. A failure in the DC bus regulation—due to capacitor dry-out—results in "ripple carry-over," manifesting as audible vibration in connected loads and potential hardware reboots. quality consistency is managed through serialized factory acceptance tests (FAT) documenting harmonic rejection under 100% load steps. The internal layout utilize conduction-cooled heatsinks and modular fan trays to stabilize component temperatures in dense equipment racks, ensuring the UPS serves as a stable energy asset for the facility operator.
Operational efficiency is achieved through the system’s ability to maintain tight voltage regulation within ±1% across the entire power span, an essential operational standard for sensitive laboratory and IT nodes. functional performance centers on the unit’s support for parallel operation; the RT series utilizes active current-sharing logic to allow multiple units to operate in N+1 redundancy configurations. In a real operational scenario, a failure in the synchronization link—due to localized EMI—leads to "circulating currents" that generate excessive heat in the shared busbars—effectively decommissioning the facility's power protection. To mitigate this, the unit utilizes high-fidelity digital sync links. if the internal battery management system (BMS) detects a cell failure through its automated discharge testing, it triggers an early-warning alarm via the network interface. Thermal management of the modular fan trays is critical; the unit features speed-controlled fans that modulate based on the internal thermal load to reduce energy waste. By providing a clean and deterministic signal for power status, the enclosure improves the situational awareness of the facility team, ensuring that thermal thresholds are accurately tracked for institutional maintenance audits.
Designed for distributed IT, laboratory suites, and localized industrial control systems, the RT series is configured for the logistical requirements of multimodal procurement. Units ship in reinforced cartons on palletized skids with moisture-barrier film and anti-vibration inserts to protect the sensitive internal inductors and logic boards during transit. Failure to implement shock-mitigating packaging can result in "joint fatigue," leading to micro-cracks in the board solder and intermittent faults upon site arrival. For international procurement, supply-readiness is supported through serialized performance verify logs and compliance declarations provided with each shipment (CE/UL). Export-ready documentation include unit configuration snapshots and certificates of conformity provided with each lot to facilitate institutional asset registration. Packaging utilize desiccant pouches to prevent terminal oxidation during maritime transit. OEM branding and private-label firmware options are available under contract, allowing integrators to deliver branded suites with serialized records. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global markets.
Inclusive of all taxes
You Save: 0
Amritsar , India
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler
GST- 03abgcs0227d1zz