• Key Features & Attributes
  • Ratings & Reviews
  • Know your Supplier
  • Product description from supplier

Delta UPS - DPS Series 2.0 Three Phase

Inclusive of all taxes

The Delta UPS - DPS Series 2.0 Three Phase is a high-performance uninterruptible power supply designed specifically for industrial applications requiring dependable three-phase power protection. Belonging to the Delta Modulon NH Plus Series, this UPS unit delivers capacities ranging from 20 kVA to 480 kVA (equivalent to 18 kW to 108 kW), making it ideal for medium to large-scale industrial power backup needs. Featuring a robust tower form factor with dimensions 520 x 975 x 1695 mm and weighing 260 kg, this UPS combines modular design engineering with hot-swappable capabilities to ensure maximum uptime and minimal maintenance interruptions. Operating at a very low audible noise level of 70 dBA, the device supports wide relative humidity tolerance (0 to 90% non-condensing), making it suitable for diverse industrial environments. Its 94% high efficiency and low total harmonic distortion (iTHD 0.99) guarantee excellent energy savings and power quality. The unit incorporates advanced N+X redundancy at both module and system levels, redundant auxiliary power and control circuits, inbuilt static bypass, and maintenance switches to ensure high reliability and availability for mission critical applications. Additionally, it includes multi-language LCD display, LED status indicators, smart communication slots, and programmable dry contacts enhancing operational ease and integration. Optional external battery cabinets are available for extended backup durations. This UPS system sets new standards in energy-efficient, scalable, and resilient power protection solutions.

Key Features

Features Description
Capacity Range 20-480 kVA (18-108 kW)
Configuration 3 Phase IN - 3 Phase OUT
Form Factor Tower Model
Efficiency Industry leading 94%
Redundancy N+X module and system level redundancy
Hot-Swappable Modules Ensures uninterrupted operation during maintenance
Noise Level 70 dBA
Dimensions (W x D x H) 520 x 975 x 1695 mm
Weight 260 kg
Humidity Tolerance 0 - 90% non-condensing
Power Factor Output power factor up to 0.9
Low Harmonic Distortion iTHD 0.99
User Interface Multi-language LCD, LED status indicators
Communication Two smart slots, six programmable dry contact outputs
Additional Features Inbuilt maintenance and static bypass switch
Optional Accessories External battery cabinet for longer backup time
Attributes Description
Brand Delta
Model Name/Number Delta NH Plus Series
Capacity 20-480 kVA
Power Rating (kW) 18-108 kW
Configuration 3 Phase IN - 3 Phase OUT
Form Factor Tower Model
Audible Noise 70 dBA
Weight 260 kg
Usage/Application Industrial
Dimensions (W x D x H) 520 x 975 x 1695 mm
Relative Humidity 0 ~ 90% (non-condensing)
Availability In Stock
Power Quality 94% efficiency, iTHD 0.99, PF up to 0.9
Redundancy N+X redundancy at module and system level
Maintenance Hot-swappable modules, inbuilt maintenance bypass
Display and Control Multi-language LCD, LED indicators, smart slots, programmable contacts

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

Yes, the UPS features hot-swappable modular structures allowing uninterrupted operation during maintenance.

The system supports up to 480 kVA by paralleling 4 units of 120 kVA each.

N+X redundancy provides module and system level fault tolerance, ensuring continued operation even if one or more modules fail.

Yes, optional external battery cabinets are available for extended backup duration.

Yes, it offers a multi-language LCD display, LED status indicators, smart communication slots, and programmable dry contacts.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Brand: shakti power solutions

Country Of Origin: India

N series 6-10kVA UPS 6kVA – Single-Phase 6kVA industrial energy module

N series 6-10kVA UPS 6kVA is a single-phase industrial power system optimized for high-density server racks and medium-sized institutional installations requiring continuous mains conditioning and precision regulation. Utilizing an online double-conversion topology, the unit architecture isolates critical loads from grid-borne disturbances, delivering regulated voltage and frequency stability suitable for sensitive analytical and clinical equipment. The design features configurable battery autonomy through external rack support and integrated SNMP monitoring for facility-wide telemetry. Units are prepared for consolidated deliveries with mounting hardware and battery interconnect panels. Supply-readiness is managed through lot-based performance reports and harmonic distortion data, addressing the technical requirements of procurement managers seeking high-availability power with documented compliance for site acceptance testing and energy management in multi-site rollouts within Exide battery distribution frameworks.

Key Features

  • 6 kVA Continuous rating → provides a robust power pathway for medium-density IT aggregation points and critical process instrumentation panels.
  • Configurable battery autonomy → utilize external rack support with adjustable charger profiles to meet site-specific backup duration and recharge targets.
  • Integrated monitoring suite → features SNMP and relay outputs to enable real-time telemetry and event-triggered alarms for building management systems (BMS).

Technical Attributes

  • Rated Power: 6 kVA / 5.4 kW → primary selection parameter for facility load planning and protection coordination.
  • Output Fidelity: <1% Voltage tolerance → essential parameter for ensuring the stability of high-frequency IT and medical devices.
  • Communications: SNMP + Dry contacts → selection parameter defining the granularity of remote monitoring and event logging.
  • Cooling: Forced convection with sensors → determines the airflow requirements and allowable thermal load within the rack.

Electrical Topology and Control Logic of the 6 kVA Industrial UPS

The technical framework of the Delta N series 6-10kVA UPS 6kVA utilize an inverter-rectifier architecture where high-frequency PWM switching synthesize a pure AC sine wave. The structural reasoning for this double-conversion logic is to provide "safe-state isolation"—at all times, the load is fed by a regulated DC bus, shielding it from mains sags, surges, and frequency fluctuations. measurement physics rely on a high-speed feedback loop; a failure in the voltage regulation circuit—due to component drift—leads to "waveform distortion," manifesting as harmonic heating in downstream server power supplies. This failure mode results in a 20% increase in energy waste and potential hardware failures. Quality consistency is managed through serialized performance curves that document the unit's regulation accuracy under 0% to 100% load variations. The internal control system partition protection logic from communication logic to prevent "firmware hang" failure modes from decommissioning the power path. If the unit detects an internal bus fault, the high-speed static bypass executes a zero-break transfer to mains, ensuring load continuity while the fault is remediated.

Functional Performance and operational stability in High-Density Racks

Operational efficiency is achieved through the UPS’s high-efficiency ECO mode and intelligent fan speed control, which reduce the facility’s localized heat load and energy overhead. functional performance centers on the unit’s ability to handle high motor-start inrush currents; failure to provide sufficient current-shaping results in "bypass trips" during equipment startup—effectively decommissioning the protection for all other rack modules. The 6 kVA unit utilize integrated thermal sensors that monitor IGBT and heatsink temperatures; if temperatures exceed safe thresholds—due to a fan failure—the unit triggers a "thermal alarm" and executes a controlled shutdown to prevent semiconductor rupture. In a real operational scenario, a failure to configure the charger profile correctly for the external Exide bank leads to "electrolyte dry-out" or sulfation, manifesting as a sudden loss of backup minutes during a grid outage. Integrated diagnostics report battery state-of-health (SoH) via the SNMP interface, enabling B2B facility managers to implement event-driven maintenance schedules. By establish a documented baseline of THDi (Total Harmonic Distortion), the operator effectively improves the facility's power quality, reducing utility penalties and energy costs.

Institutional Deployment and Logistical Readiness for Infrastructure Rollouts

Intended for medium data rooms, industrial control hubs, and clinical support circuits, the 6 kVA module is configured for the logistical requirements of multimodal multi-site procurement. Units ship in palletized crates with anti-vibration inserts and moisture-barrier film to protect the delicate logic boards and power modules during transport. Failure to implement shock-mitigating packaging can lead to "transformer humming" and loose electrical joints, manifesting as high-impedance faults weeks after installation. For international procurement, supply-readiness is supported through serialized test certificates and wiring diagrams (CE/IEC). Export-ready documentation include technical manuals and commissioning checklists provided with each lot to facilitate institutional asset registration and customs review. Packaging utilize humidity-control liners to prevent terminal oxidation during maritime transit. OEM branding and private-label firmware profiles are available for system builders requiring branded power protection. This high-authority approach ensure procurement teams receive verified, site-ready hardware that meet the performance and safety requirements of global manufacturing and healthcare markets, providing the logistical transparency needed for large-scale asset management.

Frequently Asked Questions

  • How is the autonomy runtime configured? Autonomy is achieved by selecting an external battery capacity (26Ah to 150Ah) and adjusting the charger setpoints in the firmware.
  • Which communication interfaces are standard? The unit includes SNMP, USB, RS232, and dry-contact relay outputs for comprehensive monitoring.
  • What cooling requirements exist for the rack? Forced convection with front-to-back airflow is required; ensure specified clearances are maintained for thermal derating compliance.
  • What documentation is supplied with shipments? Deliveries include serialized performance test logs, wiring schematics, and lot-level inspection certificates.
  • Are formal standard references provided? Yes, batch test reports and conformity documents (IEC/ISO) accompany all lots.


Electrical Equipment And Supplies

Uninterruptible Power Supply (ups)

shakti power solutions

Delta UPS

DPS Series 2.0

Three Phase UPS

20-480 KVA UPS

High Efficiency UPS

Industrial UPS

Hot-swappable UPS

Modular UPS

N+X Redundancy UPS

Delta NH Plus Series

Delta UPS - DPS Series 2.0 Three Phase

Inclusive of all taxes

You Save: 0

Send Inquiry
shakti power solutions pvt limited

Amritsar , India

Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler

GST- 03abgcs0227d1zz