• Key Features & Attributes
  • Ratings & Reviews
  • Know your Supplier
  • Product description from supplier

Delta 2 kVA INX (Internal Battery)

Inclusive of all taxes

The Delta 2 kVA INX with Internal Battery is a reliable and efficient uninterruptible power supply (UPS) solution designed to deliver consistent power backup for critical industrial applications. Tailored for environments that demand uninterrupted operation, this UPS offers robust capacity support alongside advanced battery integration, ensuring seamless energy delivery during power outages. Engineered for industrial settings with a tower form factor, the Delta 2 kVA INX provides stable 50/60 Hz frequency output and operates efficiently within a temperature range of 0 to 40°C. Its compact design supports ease of installation and maintenance, while the internal battery ensures immediate and dependable backup without the need for external battery systems. With an audible noise profile ideal for industrial environments and a one-year warranty, it is crafted to meet high-performance standards. This UPS is best suited for businesses seeking a dependable power continuity solution that combines compact size with industrial-grade reliability.

Key Features

Features Description
Capacity 2 kVA
Battery Type Internal Battery
Form Factor Tower
Operating Temperature 0 to 40°C
Frequency 50/60 Hz
Warranty 1 Year
Output Phase 3:3
Audible Noise Level Optimized for Industrial Use
Model Delta 2 kVA INX
Weight Range Not Specified for this model
Attributes Description
Brand Vertiv Liebert
Model Name/Number Liebert RG
Capacity Range 40 kVA - 250 kVA (General Series Range)
Applicable Model Capacity 2 kVA (Specific Product)
Phase 3:3
Weight Not Specified for Delta 2 kVA INX
Warranty 1 Year
Operating Temperature 0 to 40°C
Form Factor Tower
Frequency 50/60 Hz
Internal Battery Yes
Audible Noise Suitable for Industrial Applications

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

Yes, the Delta 2 kVA INX includes an internal battery, providing immediate power backup without the need for external battery units.

This UPS is designed primarily for industrial applications requiring reliable power backup in environments with 3-phase 3-wire power systems.

The UPS operates efficiently within a temperature range of 0 to 40 degrees Celsius.

Yes, it supports both 50 Hz and 60 Hz frequency, making it compatible with various international power standards.

It features a tower form factor, allowing flexible installation in industrial environments with limited rack space.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Brand: shakti power solutions

Country Of Origin: India

Delta 2 kVA INX UPS – Internal Battery Module

Delta 2 kVA INX is a compact online double-conversion UPS module featuring an integrated internal battery bank for single-phase critical loads. Utilizing a high-density chassis, the unit provides continuous conditioned power with zero transfer time for small IT racks and medical point-of-care devices. The architecture emphasizes a minimal footprint and front-access service trays to reduce maintenance duration. Units are prepared for large-volume distribution, shipping palletized with vibration dampers and shock-rated trays. Supply-readiness is managed through lot-based serialization and factory test reports, addressing the requirements of facility engineers seeking verified, site-ready energy assets for remote communication nodes and retail servers requiring documented state-of-health (SoH) metrics for institutional asset registration. Packaging includes moisture-barrier wrapping for maritime logistics.

Key Features

  • Integrated sealed battery bank → maximizes equipment room area by housing energy storage within the primary UPS cabinet, eliminating the requirement for external battery racks.
  • Double-conversion online logic → provides complete isolation of the load from grid sags, surges, and frequency fluctuations, delivering a regulated sine-wave output at all times.
  • Front-access service architecture → features removable battery trays and power modules to facilitate rapid field replacement and minimize mean time to repair (MTTR).

Technical Attributes

  • Rated Power: 2 kVA / 1.8 kW → primary selection parameter for matching localized sensor arrays and IT workstation loads.
  • Internal Energy Storage: Sealed VRLA → determines the primary autonomy window for graceful system shutdowns and identifies ventilation requirements.
  • Cooling: Sensor-regulated Forced-Air → features redundant fans and filtered air paths to maintain thermal limits under continuous operation.
  • Traceability: Serialized Unit FAT → provided per unit to support procurement quality control and site acceptance testing.

Delta 2 kVA INX UPS — Internal Battery Architecture Logic

The technical framework of the Delta 2 kVA INX (Internal Battery) utilize a high-fidelity power stage where the rectifier, inverter, and energy storage modules are integrated within a single high-stiffness metallic cabinet. The structural reasoning for the internal battery trays is to maintain a "tight electrical coupling"—by minimizing the length of the DC bus cables, the unit reduces electromagnetic interference (EMI) and localized impedance sags. measurement physics rely on high-speed transducers that monitor the state-of-charge (SoC) and cell-level voltage balance. A failure in the battery charging circuit—due to firmware drift or localized surge damage—leads to "overcharge heating," manifesting as container swelling and potential fire hazards. Quality consistency is managed through serialized test reports documenting battery discharge curves under full load. The internal layout utilizes segregated thermal channels to protect the high-frequency power semiconductors from the heat generated by the energy storage bank during discharge events, ensuring the UPS serves as a stable energy asset.

Functional Performance and Operational Efficiency in Medical Suites

Operational efficiency is achieved through the system’s high-frequency conversion logic, which delivers peak efficiency even at partial loads, an essential operational standard for medical point-of-care workstations. Functional performance centers on the unit’s thermal stability; if the unit detects a fan motor failure through its monitoring interface, it triggers a diagnostic alarm and initiates a fail-safe mode to prevent IGBT rupture. In a real operational scenario, a failure in the moisture seal—due to incorrect installation in unconditioned telecom closets—leads to "surface tracking" on the PCBA, effectively decommissioning the control logic. The INX series utilizes conformally coated electronics to mitigate this risk. if the unit detects a battery end-of-life condition through its automated impedance monitoring, it provides a preemptive maintenance alert via its digital interface. maintenance procedures are simplified by the front-access design, effectively lowering the mean time to repair (MTTR) by enabling technicians to swap battery trays without Removing the UPS from the equipment rack. By providing a stable and traceable environmental signal, the unit improves the situational awareness of the facility management team.

Institutional Deployment and Logistical Readiness for multi-site rollouts

Designed for small server rooms, network closets, and medical workstations, the 2 kVA INX is configured for the logistical requirements of project-scale procurement. Units ship on palletized skids with vibration-damping inner trays and shock indicators to protect the sensitive internal inductors and electrodes during transit. Failure to implement shock-mitigating packaging can lead to "transformer humming" or loose joints in the battery-to-terminal assembly, manifesting as intermittent power loss upon site arrival. For international procurement, supply-readiness is supported through lot-based technical specifications and factory test certificates (ISO/CE). Export-ready documentation include unit configuration snapshots and installation checklists provided with each shipment to facilitate institutional asset registration. Packaging utilize moisture-barrier covers and desiccants to prevent terminal oxidation during maritime freight. OEM branding and custom firmware configurations are available, allowing buyers to standardize their fleet appearance. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global manufacturing markets.

Frequently Asked Questions

  • What battery chemistry is provided as standard? Sealed valve-regulated lead-acid (VRLA) batteries are standard; high-density lithium-ion modules are available for specialized lifecycle needs.
  • Can I add external battery cabinets for longer runtime? Yes; the 2 kVA INX architecture includes a dedicated DC port to facilitate extended autonomy profiles.
  • How is moisture risk managed during sea transport? Every unit is enclosed in a vacuum-sealed vapor-barrier bag with desiccant pouches inside a reinforced crate.
  • What is the usable output power? The unit delivers approximately 1800W of active power, depending on the load power factor.
  • What documentation accompanies each lot? Shipments include serialized factory test reports, wiring diagrams, and quality inspection summaries.


Electrical Equipment And Supplies

Uninterruptible Power Supply (ups)

shakti power solutions

Delta 2 KVA UPS

Internal Battery UPS

Tower UPS 2 KVA

Industrial UPS Backup

Liebert UPS 2 KVA

Vertiv Delta INX UPS

Power Backup Systems 2 KVA

Delta 2 kVA INX (Internal Battery)

Inclusive of all taxes

You Save: 0

Send Inquiry
shakti power solutions pvt limited

Amritsar , India

Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler

GST- 03abgcs0227d1zz

  • Secure
    Transaction

  • Day
    Dispatch

Report a problem with this product