• Key Features & Attributes
  • Ratings & Reviews
  • Know your Supplier
  • Product description from supplier

Delta UPS NH Plus Series, Three Phase 20kVA - 480kVA, For Industrial, 20-480 kVA

Inclusive of all taxes

The Delta UPS NH Plus Series is a robust and reliable three-phase uninterruptible power supply (UPS) system designed specifically for industrial applications. With a capacity ranging from 20 kVA to 480 kVA, this UPS series ensures continuous power protection and high performance for critical operations in demanding industrial environments. The NH Plus Series features true online double-conversion topology with zero transfer time to battery, guaranteeing seamless power supply and preventing downtime. Equipped with an advanced Digital Signal Processor (DSP) controller, it offers rapid computation capabilities and a streamlined control circuit for improved operational stability. The wide input voltage range allows the UPS to perform efficiently even in harsh electrical environments, minimizing power disruptions and equipment damage. Its tower form factor and compact dimensions make it convenient for industrial setups where space optimization is essential. With a power rating between 20 kVA to 480 kVA and superior energy efficiency, the Delta UPS NH Plus Series is an ideal solution for businesses seeking dependable industrial power backup with ease of scalability and maintenance.

Key Features

Features Description
Capacity Range 20 kVA to 480 kVA
Phase Configuration Three Phase
Topology True Online Double-Conversion
Transfer Time Zero Transfer Time to Battery
Controller Advanced DSP (Digital Signal Processor) Controller
Input Voltage Range Wide input range for harsh electrical environments
Form Factor Tower Model
Audible Noise Level < 43 dBA
Power Rating (kVA) 20 kVA - 480 kVA
Application Industrial use for reliable power protection
Attributes Description
Brand Delta
Model Name/Number Delta UPS NH Plus Series
Capacity 20 kVA to 480 kVA
Phase Three Phase
Topology True Online Double-Conversion
Transfer Time Zero to battery
Controller Advanced DSP Controller
Input Voltage Range Wide Range for harsh environments
Audible Noise < 43 dBA
Form Factor Tower
Dimensions (W x D x H) 190 x 390 x 325 mm (model dependent)
Relative Humidity 5% to 95% (non-condensing)
Power Rating (kW) 18 - 432 kW (approximate based on kVA and power factor)
Application Industrial power protection and backup

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

The Delta UPS NH Plus Series supports capacities up to 480 kVA.

It uses a True Online Double-Conversion topology for continuous and reliable power.

Yes, it features a wide input voltage range designed to handle harsh electrical conditions.

This series supports a Three Phase configuration ideal for industrial power needs.

An advanced Digital Signal Processor (DSP) controller is used for fast and stable UPS operation.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Brand: shakti power solutions

Country Of Origin: India

DPS Series 2.0 Three Phase UPS – Three-Phase 2.0 energy protection System

DPS Series 2.0 Three Phase UPS is a high-availability power protection system engineered for industrial and commercial installations requiring distributed redundancy and modular expansion. Utilizing scalable power modules and a centralized control chassis, the system deliver continuous online double-conversion mains conditioning for high-mass energy storage and critical process loads. The unit architecture features hot-swappable power modules and integrated diagnostics to minimize mean time to repair (MTTR) without interrupting the protected load. Palletized shipments include module racks and control panels with lot-specific electrical test reports. Supply-readiness is managed through factory-verified load-sharing tests and commissioning checklists, addressing the technical requirements of procurement managers in data centers and hospital cores seeking high-availability power with documented redundancy topologies for site acceptance and asset tracking within Exide battery distribution frameworks.

Key Features

  • Three-phase modular architecture → provides balanced energy distribution for large industrial loads and enables staged capacity expansion without system decommissioning.
  • Distributed parallel redundancy → utilize N+1 or parallel configurations to eliminate single-point failures and ensure continuous system oversight during module maintenance.
  • Integrated diagnostic telemetry → features on-board metering and remote alarm reporting to facilitate proactive maintenance and energy accounting across the facility.

Technical Attributes

  • Phase Configuration: 3-Phase Input/Output → selection criterion for ensuring electrical compatibility with high-voltage facility grids and generator sets.
  • Modularity: Hot-swappable power stages → selection parameter for reducing MTTR and maximizing system availability during service events.
  • Communications: Network + Relay interfaces → determines compatibility with existing building management systems (BMS) and SCADA platforms.
  • Redundancy: N+X Configurable → selection parameter defining the fault tolerance level required for mission-critical institutional infrastructure.

Mechanical and Electrical Composition of the DPS Series 2.0

The technical framework of the DPS Series 2.0 Three Phase UPS utilize a high-density modular architecture where discrete rectifier, inverter, and control modules are integrated into a common high-current busbar chassis. The structural reasoning for this modularity is to provide "fault containment"—a failure in one power module—due to IGBT failure or capacitor dry-out—can be isolated and replaced while the remaining modules maintain full system output. Without this specific architecture, a single component fault in a three-phase system would decommissioning the entire 500 kVA load, leading to catastrophic production loss. Measurement physics rely on active current-sharing logic between modules; a failure in the synchronization bus results in "circulating currents" that generate excessive heat in the busbars and manifest as localized thermal hotspots. Quality consistency is managed through serialized factory acceptance tests (FAT) that include load-sharing verification and high-speed transfer testing between modules and the centralized static bypass. The internal chassis utilizes insulated bus-duct technology to prevent arc-flash propagation between modules, a critical safety standard for live-service data halls.

Functional Performance and operational efficiency in Mission-Critical Sites

Operational efficiency is achieved through the system’s ability to optimize the number of active modules relative to the total load, maintaining high conversion efficiency even during partial-load conditions. functional performance centers on the unit’s ability to sustain regulated three-phase output under extreme load transients. In a real operational scenario, a failure in the fan modulation logic—due to sensor drift—leads to localized overheating of the power semiconductors, triggering an automatic move to static bypass. The DPS 2.0 series utilizes redundant cooling fans in each module; if a fan fails, the module can continue to operate at a derated capacity until a replacement is fitted—effectively reducing the risk of a "thermal trip." The centralized control chassis manages battery charging and health monitoring for large Exide banks. failure to management the "equalization charge" across the parallel banks results in voltage dispersion and permanent capacity loss. If the system detects a catastrophic bus fault, the bypass logic executes a zero-break transfer to utility mains. By providing detailed telemetry on harmonic emission and load profiles, the UPS allows B2B facility managers to accurately account for energy throughput and implement predictive maintenance routines before a component failure occur.

Institutional Deployment and Logistical Readiness for Data Centers

Suitable for large-scale IT centers, hospital power cores, and manufacturing complexes, the DPS 2.0 is configured for the logistical requirements of multimodal multi-site rollouts. Units ship in reinforced skid-mounted crates with internal mechanical restraints to protect the sensitive power electronics during the high-G loads of transport. Failure to implement shock-monitored palletization can result in "busbar misalignment," leading to high-impedance electrical joints and potential localized fires upon site commissioning. For international procurement, supply-readiness is supported by lot-specific test certificates and technical dossiers that facilitate customs review and institutional asset registration (CE/ISO). Export-ready documentation include unit configuration snapshots and commissioning checklists provided with each shipment. Packaging utilize moisture-barrier wrapping and desiccants to prevent terminal oxidation during maritime freight. OEM private-label branding and custom HMI settings are supported for system builders requiring branded power protection suites. This high-authority approach ensure procurement teams receive verified, site-ready energy assets that meet the safety and performance standards of global markets, providing the transparency required for institutional asset tracking and regulatory safety audits.

Frequently Asked Questions

  • Can modules be serviced while the UPS is online? Yes; hot-swappable power modules allow for individual module maintenance without interrupting the protected load.
  • What redundancy levels are supported? The platform supports N, N+1, and distributed parallel redundancy configurations based on site availability targets.
  • How is thermal management addressed in the chassis? Each module features independent forced-air cooling with redundant fans and integrated thermal sensors.
  • What documentation is supplied for commissioning? Every unit ships with serialized electrical test reports, wiring diagrams, and a commissioning checklist.
  • Is there support for different battery types? The control chassis include pre-configured profiles for VRLA, NiCd, and Lithium-Ion battery banks.


Electrical Equipment And Supplies

Uninterruptible Power Supply (ups)

shakti power solutions

Delta UPS NH Plus

20-480 KVA UPS

Industrial UPS

Three Phase UPS

True Online UPS

High Capacity UPS

Industrial Power Backup

DSP Controller UPS

Delta UPS NH Plus Series, Three Phase 20kVA - 480kVA, For Industrial, 20-480 kVA

Inclusive of all taxes

You Save: 0

Send Inquiry
shakti power solutions pvt limited

Amritsar , India

Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler

GST- 03abgcs0227d1zz

  • Secure
    Transaction

  • Day
    Dispatch

Report a problem with this product