The Delta UPS NH Plus Series is a robust and reliable three-phase uninterruptible power supply (UPS) system designed specifically for industrial applications. With a capacity ranging from 20 kVA to 480 kVA, this UPS series ensures continuous power protection and high performance for critical operations in demanding industrial environments. The NH Plus Series features true online double-conversion topology with zero transfer time to battery, guaranteeing seamless power supply and preventing downtime. Equipped with an advanced Digital Signal Processor (DSP) controller, it offers rapid computation capabilities and a streamlined control circuit for improved operational stability. The wide input voltage range allows the UPS to perform efficiently even in harsh electrical environments, minimizing power disruptions and equipment damage. Its tower form factor and compact dimensions make it convenient for industrial setups where space optimization is essential. With a power rating between 20 kVA to 480 kVA and superior energy efficiency, the Delta UPS NH Plus Series is an ideal solution for businesses seeking dependable industrial power backup with ease of scalability and maintenance.
Key Features
| Features | Description |
|---|---|
| Capacity Range | 20 kVA to 480 kVA |
| Phase Configuration | Three Phase |
| Topology | True Online Double-Conversion |
| Transfer Time | Zero Transfer Time to Battery |
| Controller | Advanced DSP (Digital Signal Processor) Controller |
| Input Voltage Range | Wide input range for harsh electrical environments |
| Form Factor | Tower Model |
| Audible Noise Level | < 43 dBA |
| Power Rating (kVA) | 20 kVA - 480 kVA |
| Application | Industrial use for reliable power protection |
| Attributes | Description |
|---|---|
| Brand | Delta |
| Model Name/Number | Delta UPS NH Plus Series |
| Capacity | 20 kVA to 480 kVA |
| Phase | Three Phase |
| Topology | True Online Double-Conversion |
| Transfer Time | Zero to battery |
| Controller | Advanced DSP Controller |
| Input Voltage Range | Wide Range for harsh environments |
| Audible Noise | < 43 dBA |
| Form Factor | Tower |
| Dimensions (W x D x H) | 190 x 390 x 325 mm (model dependent) |
| Relative Humidity | 5% to 95% (non-condensing) |
| Power Rating (kW) | 18 - 432 kW (approximate based on kVA and power factor) |
| Application | Industrial power protection and backup |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
The Delta UPS NH Plus Series supports capacities up to 480 kVA.
It uses a True Online Double-Conversion topology for continuous and reliable power.
Yes, it features a wide input voltage range designed to handle harsh electrical conditions.
This series supports a Three Phase configuration ideal for industrial power needs.
An advanced Digital Signal Processor (DSP) controller is used for fast and stable UPS operation.
Brand: shakti power solutions
Country Of Origin: India
DPS Series 2.0 Three Phase UPS is a high-availability power protection system engineered for industrial and commercial installations requiring distributed redundancy and modular expansion. Utilizing scalable power modules and a centralized control chassis, the system deliver continuous online double-conversion mains conditioning for high-mass energy storage and critical process loads. The unit architecture features hot-swappable power modules and integrated diagnostics to minimize mean time to repair (MTTR) without interrupting the protected load. Palletized shipments include module racks and control panels with lot-specific electrical test reports. Supply-readiness is managed through factory-verified load-sharing tests and commissioning checklists, addressing the technical requirements of procurement managers in data centers and hospital cores seeking high-availability power with documented redundancy topologies for site acceptance and asset tracking within Exide battery distribution frameworks.
The technical framework of the DPS Series 2.0 Three Phase UPS utilize a high-density modular architecture where discrete rectifier, inverter, and control modules are integrated into a common high-current busbar chassis. The structural reasoning for this modularity is to provide "fault containment"—a failure in one power module—due to IGBT failure or capacitor dry-out—can be isolated and replaced while the remaining modules maintain full system output. Without this specific architecture, a single component fault in a three-phase system would decommissioning the entire 500 kVA load, leading to catastrophic production loss. Measurement physics rely on active current-sharing logic between modules; a failure in the synchronization bus results in "circulating currents" that generate excessive heat in the busbars and manifest as localized thermal hotspots. Quality consistency is managed through serialized factory acceptance tests (FAT) that include load-sharing verification and high-speed transfer testing between modules and the centralized static bypass. The internal chassis utilizes insulated bus-duct technology to prevent arc-flash propagation between modules, a critical safety standard for live-service data halls.
Operational efficiency is achieved through the system’s ability to optimize the number of active modules relative to the total load, maintaining high conversion efficiency even during partial-load conditions. functional performance centers on the unit’s ability to sustain regulated three-phase output under extreme load transients. In a real operational scenario, a failure in the fan modulation logic—due to sensor drift—leads to localized overheating of the power semiconductors, triggering an automatic move to static bypass. The DPS 2.0 series utilizes redundant cooling fans in each module; if a fan fails, the module can continue to operate at a derated capacity until a replacement is fitted—effectively reducing the risk of a "thermal trip." The centralized control chassis manages battery charging and health monitoring for large Exide banks. failure to management the "equalization charge" across the parallel banks results in voltage dispersion and permanent capacity loss. If the system detects a catastrophic bus fault, the bypass logic executes a zero-break transfer to utility mains. By providing detailed telemetry on harmonic emission and load profiles, the UPS allows B2B facility managers to accurately account for energy throughput and implement predictive maintenance routines before a component failure occur.
Suitable for large-scale IT centers, hospital power cores, and manufacturing complexes, the DPS 2.0 is configured for the logistical requirements of multimodal multi-site rollouts. Units ship in reinforced skid-mounted crates with internal mechanical restraints to protect the sensitive power electronics during the high-G loads of transport. Failure to implement shock-monitored palletization can result in "busbar misalignment," leading to high-impedance electrical joints and potential localized fires upon site commissioning. For international procurement, supply-readiness is supported by lot-specific test certificates and technical dossiers that facilitate customs review and institutional asset registration (CE/ISO). Export-ready documentation include unit configuration snapshots and commissioning checklists provided with each shipment. Packaging utilize moisture-barrier wrapping and desiccants to prevent terminal oxidation during maritime freight. OEM private-label branding and custom HMI settings are supported for system builders requiring branded power protection suites. This high-authority approach ensure procurement teams receive verified, site-ready energy assets that meet the safety and performance standards of global markets, providing the transparency required for institutional asset tracking and regulatory safety audits.