Inclusive of all taxes
The Delta UPS EH Series (10/15/20 kVA) is a high-performance rack-mounted uninterruptible power supply designed to deliver reliable and efficient power backup for critical applications. Built to support input voltages ranging from 175~280VAC and providing a stable 230V output, this UPS is ideal for data centers, telecommunications, manufacturing units, and server environments. Featuring a compact 2U form factor, it offers excellent power density and space-saving design. With a unity output power factor, the UPS efficiently supports critical loads without compromise. Its advanced design delivers superior energy efficiency with an AC-AC efficiency of up to 96.5% and an ECO mode efficiency of 99%, significantly reducing operational costs. A standout feature is its exclusive compatibility with Li-ion external battery cabinets, providing enhanced power density along with improved sustainability and longer battery life. The system supports parallel configurations of up to four units, enabling scalable power backup tailored to growing business requirements. This model ensures maximum reliability and continuous operation, making it the best choice for industries seeking robust and energy-saving UPS solutions.
Key Features
| Features | Description |
|---|---|
| Capacity | 10/15/20 kVA |
| Brand | Delta |
| Input Voltage Range | 175~280 VAC |
| Output Voltage | 230 V |
| Form Factor | Rack Mounted (2U) |
| Output Power Factor | Unity |
| Energy Efficiency (AC-AC) | Up to 96.5% |
| ECO Mode Efficiency | 99% |
| Battery Compatibility | Li-ion External Battery Cabinets |
| Parallel Capability | Up to 4 Units |
| Application | Data Centers, Servers, Telecommunications, Manufacturing |
| Availability | In Stock |
| Attributes | Description |
|---|---|
| Capacity Options | 10 kVA, 15 kVA, 20 kVA |
| Input Voltage | 175~280 VAC |
| Output Voltage | 230 VAC |
| Form Factor | 2U Rack Mounted |
| Output Power Factor | Unity |
| Efficiency (AC-AC) | Up to 96.5% |
| Efficiency (ECO Mode) | 99% |
| Battery Type | Li-ion External Battery Cabinets |
| Parallel Operations | Supports up to 4 Units in Parallel |
| Typical Applications | Servers, Data Centers, Telecom, Manufacturing |
| MOQ | 1 Unit |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
Yes, the Delta UPS EH Series supports parallel configuration of up to four units to provide scalable and reliable power backup for higher power requirements.
This UPS series is the first in the market to support Li-ion external battery cabinets, offering enhanced power density and sustainability.
The UPS delivers an impressive ECO mode efficiency of up to 99%, reducing energy consumption and operational costs.
Yes, the UPS is designed to handle critical loads in telecom, manufacturing, data centers and server environments with high reliability.
The UPS comes in a compact 2U rack-mounted form factor that saves valuable space in server and data center racks.
Brand: shakti power solutions
Country Of Origin: India
Delta UPS EH Series is a three-phase power protection platform offering modular power electronics and redundant control pathways for commercial and industrial conditioning. Utilizing a convertible rack/tower chassis, the system delivers conditioned output in 10 kVA, 15 kVA, or 20 kVA configurations, supporting high availability for data centers and process control rooms. The unit architecture includes configurable bypass logic and hot-swappable power modules to minimize mean time to repair (MTTR) without interrupting critical loads. Units are produced with manufacturing capacity to support large-order procurement, featuring palletized crates with vibration protection and lot traceability. Supply-readiness is managed through per-unit functional tests and burn-in logs, addressing the requirements of facility managers requiring right-sized, scalable power protection with documented performance baselines for site acceptance and integration into industrial energy management protocols.
The technical framework of the Delta UPS EH Series utilize a modular inverter-rectifier architecture where the power conversion stages are decoupled by a common DC bus. The structural reasoning for this modularity is to provide "fault isolation"—a failure in one power module—due to capacitor breakdown or IGBT failure—can be isolated immediately, allowing the redundant module or static bypass to maintain the output sine wave. Without this specific architecture, a localized component failure would decommission the entire three-phase system, leading to catastrophic downtime for connected IT or medical equipment. The mechanical layout segregates the power electronics from the sensitive control circuitry, reducing electromagnetic interference (EMI) and localized heat coupling. Power stage PCBs are conformal-coated to resist moisture-induced tracking, a critical standard for units deployed in unconditioned industrial plant rooms. Quality consistency is managed through serialized test reports that record the unit's THDv (Voltage Total Harmonic Distortion) and regulation accuracy under 100% load step changes. Failure to maintain these tolerances leads to "load hunting" and increased thermal stress on the downstream server power supplies.
Operational efficiency is achieved through the system’s high-efficiency double-conversion mode, which provides continuous isolation from grid disturbances while maintaining low operating costs. The EH Series utilize variable-speed fans that modulate based on real-time load and temperature data; a failure in the fan speed control results in excessive acoustic noise or localized overheating of the DC-link capacitors. Functional performance centers on the unit’s ability to handle high crest-factor loads typical of industrial control centers. The integrated charger management system execute temperature-compensated charging for internal or external VRLA banks. Failure to compensate for temperature—especially in warm data rooms—leads to "thermal runaway" and battery swelling, effectively reducing the energy storage capacity by 50%. If the system detects a catastrophic bus fault, the configurable bypass logic executes a zero-break transfer to mains, provided the sources are synchronized. Integrated telemetry provides real-time state-of-health (SoH) metrics and event logs via Modbus, allowing B2B facility managers to implement predictive maintenance and accurately account for the energy throughput of the critical power system.
Appropriate for commercial complexes, small-to-medium data centers, and industrial process rooms, the Delta EH Series is configured for the logistical requirements of large-order procurement. Units ship in palletized crates with anti-vibration fixtures and humidity-control liners to protect the delicate inverter electronics during multimodal transit. Failure to implement shock-mitigating packaging can lead to "latent defects" in the transformer mounts, resulting in high-impedance joints and localized hotspots upon site commissioning. For international projects, supply-readiness is supported through serialized functional verification reports and compliance declarations (CE/IEC). Export-ready documentation include configuration images, firmware versioning cards, and electrical safety certificates provided with each lot. Packaging utilize moisture-barrier wrapping and desiccant to prevent corrosion of the high-current connectors during maritime freight. OEM branding and private-label configuration options are available for system integrators requiring branded power protection suites. This systematic approach ensure procurement teams receive verified, site-ready hardware that meet the rigorous technical and safety performance standards required for international infrastructure deployments.