Inclusive of all taxes
The Eaton Dxrt-10kva with External Battery Model from the Amplon RT Series is an advanced online double-conversion UPS designed to deliver reliable power backup for critical applications. This 10kVA single-phase UPS system boasts a compact 2U form factor with dimensions of 440 x 565 x 88.2mm and weighs between 10 to 23 kg, making it suitable for space-constrained installations. Engineered with a unity output power factor, it optimizes power capacity to handle more critical loads efficiently. Offering exceptional energy savings, the UPS achieves an AC-AC efficiency of up to 96.5% and up to 99% in ECO mode, reducing operational costs. A standout feature of this model is its support for standard Li-ion external battery cabinets, enhancing power density and sustainability compared to traditional batteries. Its scalable design supports parallel operation of up to four units, ensuring increased reliability and redundancy. Ideal for mission-critical environments such as data centers, servers, telecommunications, and manufacturing, this UPS supports both single and three-phase configurations ranging from 5kVA to 20kVA. Made in India and available in stock, the Eaton Dxrt-10kva ensures robust and efficient power management tailored to demanding industrial needs.
Key Features
| Features | Description |
|---|---|
| Capacity | 10 kVA (Single Phase) |
| UPS Type | Online Double-Conversion |
| Form Factor | Compact 2U Size |
| Output Power Factor | Unity |
| Energy Efficiency | Up to 96.5% (AC-AC), 99% (ECO Mode) |
| External Battery Compatibility | Standard Li-ion External Battery Cabinets |
| Parallel Operation | Up to 4 Units |
| Application | Servers, Data Centers, Telecommunications, Manufacturing |
| Weight | 10 - 23 Kg |
| Dimensions (WxDxH) | 440 x 565 x 88.2 mm |
| Country of Origin | Made in India |
| Attributes | Description |
|---|---|
| Model Name/Number | RT Series (Dxrt-10kva) |
| Capacity Range | 5/6/8/10 kVA (Single Phase), 10/15/20 kVA (Three Phase) |
| Phase | Single and Three Phase |
| UPS Type | Online Double-Conversion |
| Output Power Factor | Unity |
| Energy Efficiency | Up to 96.5% AC-AC, 99% in ECO Mode |
| External Battery | Standard Li-ion External Battery Cabinets |
| Parallel Capacity | Up to 4 Units |
| Weight | 10 - 23 Kilograms |
| Dimensions (WxDxH) | 440 x 565 x 88.2 millimeters |
| Country of Origin | India |
| Availability | In Stock |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
Yes, the Eaton Dxrt-10kva supports parallel operation of up to four units for increased capacity and redundancy.
This UPS supports standard Li-ion external battery cabinets, offering improved power density and longer sustainability.
The Dxrt-10kva is configured as a single-phase UPS but is part of the Amplon RT Series that supports both single and three-phase UPS models ranging 5kVA to 20kVA.
The Eaton Dxrt-10kva achieves up to 99% efficiency in ECO mode, providing substantial energy savings.
Yes, it is ideal for mission-critical environments such as servers, data centers, telecommunications, and manufacturing facilities.
Brand: shakti power solutions
Country Of Origin: India
Eaton Dxrt-10kVA UPS with External Battery is a high-autonomy online double-conversion power system specifically engineered for extended runtime applications in remote IT and telecom hubs. utilizing an external battery cabinet architecture, the unit separates high-mass energy storage from the power conversion electronics, allowing for prolonged autonomy without increasing the primary UPS footprint. The design features isolated DC bus connections and dedicated ventilation to minimize thermal impact on sensitive power semiconductors. Typical supply formats include palletized UPS units with separate battery skids, featuring serialized test certificates and material trace records. Supply-readiness is managed through factory-verified load-step testing and battery capacity checks, addressing the requirements of facility managers seeking documented reliability and rapid site integration for long-duration backup requirements. Packaging utilizes shock-rated pallets and moisture-barrier liners for multimodal international transport.
The technical framework of the Eaton Dxrt-10kva With External Battery Model utilizes an online double-conversion topology where the energy storage subsystem is isolated from the primary power conversion circuitry via a high-current DC link. The structural reasoning for the external cabinet design is to provide "thermal containment"—by keeping the batteries in a dedicated ventilated rack, the system prevents "thermal runaway" common in high-density integrated units. measurement physics rely on high-fidelity current sensors that coordinate the charging and discharging cycles within ±1% accuracy. A failure in the DC bus regulation—due to component drift or surging—leads to "output sag" and erratic resets in connected network processors—a failure mode that decommissions the accuracy of localized compute nodes. Quality consistency is managed through serialized test reports documenting waveform purity under full-load discharge. The internal layout utilize vibration-damped frames and isolated DC busbars with safety interlocks to prevent live exposure during service maintenance.
Operational efficiency is achieved through the system’s high-efficiency conversion stages and its ability to handle prolonged discharge events without thermal derating, an essential operational standard for remote sites. functional performance centers on the unit’s support for proactive battery diagnostics; if the external BMS detects a cell resistance shift through its monitoring interface, it triggers an early-warning alarm for the operator. In a real operational scenario, a failure in the inrush current limiting circuit leads to "contactor pitting" or upstream breaker trips during initial power-on—effectively decommissioning the facility's power protection node. The Dxrt utilize soft-start circuitry and keyed connectors to mitigate this risk. if the unit is subjected to power fluctuations, the high-speed static bypass executes a zero-break transfer to utility mains to preserve downstream sine-wave fidelity. By providing a clean and deterministic signal for energy status, the unit improves the situational awareness of the facility management team, ensuring that backup thresholds are accurately tracked for institutional maintenance audits.
Designed for remote telecommunications sites, hospital technical rooms, and clinical equipment suites, the Dxrt-10kVA is configured for the logistical requirements of multimodal multi-site procurement. Units ship on steel-reinforced pallets with internal rigid bracing and moisture-barrier covers to protect the sensitive inductors and copper headers from transport-induced damage. Failure to implement shock-monitored packaging can result in "frame racking," leading to internal manifold leaks and potential electrical shorts upon site commissioning. For international procurement, supply-readiness is supported through serialized test records and certificates of analysis (ISO/CE). Export-ready documentation include unit configuration snapshots and material safety data sheets (MSDS) provided with each consignment to facilitate customs review and institutional asset registration. Packaging utilize humidity-control liners and desiccant to prevent terminal oxidation during maritime transit. OEM branding and custom façade options are available, allowing buyers to standardize their fleet appearance. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global manufacturing markets.
Inclusive of all taxes
You Save: 0
Amritsar , India
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler
GST- 03abgcs0227d1zz