Inclusive of all taxes
The Delta UPS HPH Series Three Phase 20 - 120 kW is a high-performance uninterruptible power supply designed for industrial and commercial applications demanding reliable three-phase power backup. Featuring IGBT-based rectifier technology and true on-line double-conversion efficiency of up to 90% with advanced DSP control, this UPS ensures uninterrupted, clean, and stable power output. It provides an ultra-wide input voltage window of 280 VAC, making it ideal for environments with poor power quality or fluctuating electrical conditions. The active input power factor correction of 0.99 and output power factor of 0.9 optimize energy efficiency and reduce power consumption. This model supports external batteries (12V/9AH) and outputs voltages of 208/220/230/240VAC, delivering dependable power ranging from 20 kW up to 120 kW. Suitable for critical infrastructure, data centers, manufacturing plants, and other industrial settings, the Delta HPH Series UPS guarantees maximum operational uptime.
Key Features
| Features | Description |
|---|---|
| Power Capacity | 20 - 120 kW three-phase power output |
| Rectifier Type | IGBT-based Rectifier |
| Efficiency | True on-line double-conversion up to 90% |
| Control Technology | DSP Control Technology for high performance and reliability |
| Input Power Factor | Active PFC of 0.99 |
| Output Power Factor | 0.9 |
| Input Voltage Range | Ultra-wide window up to 280 VAC |
| Battery Type | Supports External Batteries 12V / 9 AH |
| Output Voltage | 208/220/230/240 VAC selectable |
| Application | Designed for harsh conditions and poor power quality environments |
| Attributes | Description |
|---|---|
| Model Name/Number | LIEBERT GXTMT+CX3KVA (External Battery) |
| Power Capacity | 3000 VA / 2700 W per unit |
| Battery Type | 12 V / 9 AH (External Battery) |
| Weight | 27.6 kg |
| Dimensions (mm) | 421 x 190 x 318 |
| Output Voltage Options | 208/220/230/240 VAC |
| Rectifier Technology | IGBT-based |
| Efficiency | Up to 90% |
| Input Power Factor | 0.99 (Active PFC) |
| Output Power Factor | 0.9 |
| Input Voltage Window | Up to 280 VAC |
| Availability | In Stock |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
Yes, it supports external batteries of 12V / 9 AH for extended backup durations.
The UPS operates effectively within an ultra-wide input voltage window up to 280 VAC, suitable for harsh electrical conditions.
Yes, its active input power factor correction and stable output make it ideal for environments with poor power quality.
It supports selectable output voltages of 208, 220, 230, and 240 VAC.
It employs advanced DSP Control Technology for high performance and system reliability.
Brand: shakti power solutions
Country Of Origin: India
Delta HPH Series 20-120 kW is a modular three-phase uninterruptible power system engineered for mid-to-large industrial applications requiring scalable capacity and synchronized load management. utilizing high-density power modules, the system delivers contiguous power increments with tight voltage regulation under variable thermal and equipment loads. The unit architecture features front-access maintenance panels and mechanically keyed modules to minimize mean time to repair (MTTR) and simplify field installation. Units are configured for staged expansion, shipping on skids with reinforced internal bracing. Supply-readiness is managed through serialized module verification and factory harmonics reports, addressing the requirements of campus power hubs and manufacturing plants seeking modular environmental and energy control with documented compliance for institutional asset registration and multi-site rollouts.
The technical framework of the Delta HPH Series 20 - 120 kW utilize a welded internal metallic frame specifically engineered to support high-mass energy storage cabinets and high-current busbars. The structural reasoning for the modular power blocks is to provide "safe-state isolation"—technicians can isolate and replace a faulty module without breaching the primary containment of the facility's power supply. measurement physics rely on redundant microcontrollers that coordinate the high-speed PWM switching across the parallel bank. A failure in the inter-module synchronization bus—due to localized EMI—leads to "circulating currents" that generate excessive heat in the shared busbars, decommissioning the energy efficiency of the entire site. Quality consistency is managed through serialized module verification and factory-performed harmonics mapping. The internal layout utilize separate battery enclosures with dedicated ventilation to prevent "thermal cross-talk" from the power semiconductors to the energy storage cells—a failure mode that results in accelerated battery degradation.
Operational efficiency is achieved through the unit’s ability to maintain tight voltage regulation within ±1% across the entire power span, an essential operational standard for campus-wide IT and utility centers. functional performance centers on the system’s support for predictive maintenance; integrated diagnostics analyze temperature and current trends to recommend preemptive module replacement before a hard failure occur. In a real operational scenario, a failure in the static bypass logic—used during maintenance transfers—leads to "load drop," decommissioning the facility's situational awareness. To mitigate this, the HPH series utilize high-speed SCR-based bypass modules. if the unit detects a significant input phase imbalance, it triggers a protective alarm and transitions to battery power to preserve the downstream sine-wave fidelity. By providing a clean and deterministic signal for energy status, the enclosure improves the overall reliability of the critical process node, facilitating institutional energy accounting and regulatory maintenance audits.
Designed for campus power hubs, medium data centers, and industrial manufacturing plants, the HPH 20-120 kW is configured for the logistical requirements of multimodal procurement. Units ship in steel-reinforced crates with internal rigid bracing and shock indicators to protect the sensitive internal processors and bus-duct connections from transport-induced damage. Failure to implement shock-monitored packaging can result in "joint stress," leading to localized high-resistance contacts and potential localized fires upon site commissioning. For international procurement, supply-readiness is supported through lot-specific test certificates and quality inspection reports (ISO/CE). Export-ready documentation include unit configuration snapshots and installation checklists provided with each shipment to facilitate institutional asset registration. Packaging utilize moisture-barrier covers and desiccants to prevent oxidation of the electrical terminals during maritime transit. OEM branding and private-label firmware options are available under contract, providing procurement teams with verified hardware that meet the performance requirements of global manufactured utility markets.
Inclusive of all taxes
You Save: 0
Amritsar , India
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler