Inclusive of all taxes
The Delta N Series 1-3kVA UPS is a reliable and efficient uninterruptible power supply system designed to provide seamless power backup in critical applications. Specifically engineered to deliver 6000 Watts of power, this UPS supports 220V input and output voltages with a one-phase input and one-phase output configuration, making it ideal for environments requiring stable single-phase power continuity. With an impressive efficiency rating of 93%, this tower-form factor UPS ensures reduced energy losses and lower operational costs. The unit is equipped with a 2-meter power cord for flexible installation and features low audible noise operation to maintain a quiet work environment. It is engineered to meet the needs of business setups that demand consistent and reliable backup power, maintaining uptime during power fluctuations or outages. This Delta N Series UPS from Shakti Power Solutions Pvt Limited offers factory-direct pricing and a minimum order quantity of just one unit, ensuring flexible procurement for B2B buyers seeking high-performance UPS solutions for critical infrastructure protection.
Key Features
| Features | Description |
|---|---|
| Power Capacity | 6000 Watts (6 kW) |
| UPS Series | Delta N Series (1-3kVA range) |
| Input Voltage | 220V Single Phase |
| Output Voltage | 220V Single Phase |
| Efficiency | 93% efficient power conversion |
| Configuration | 1 Phase IN - 1 Phase OUT |
| Form Factor | Tower type design |
| Power Cord Length | 2 meters |
| Audible Noise Level | Low noise operation |
| MOQ | 1 unit |
| Attributes | Description |
|---|---|
| Brand | Delta |
| Model Name/Number | New N 6kwatts |
| Input Voltage | 220V Single Phase |
| Output Voltage | 220V Single Phase |
| Power Capacity | 6000 Watts |
| Efficiency | 93% |
| Configuration | 1 Phase IN - 1 Phase OUT |
| Form Factor | Tower |
| Power Cord Length | 2 meters |
| Noise Level | Audible noise, low |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
The Delta N series 6000 Watts UPS supports 220V single phase input and output voltage configuration.
Yes, this UPS features low audible noise, making it suitable for quiet office or operational environments.
This Delta N series UPS operates at a high efficiency of 93%, reducing energy waste during power conversion.
The minimum order quantity for the Delta N series UPS from Shakti Power Solutions Pvt Limited is 1 unit.
This Delta N series UPS supports only single-phase input and output power configuration.
Brand: shakti power solutions
Country Of Origin: India
Exide Powersafe Battery 42ah is a mid-capacity sealed lead-acid unit designed for UPS and standby applications requiring moderate autonomy in compact cabinet footprints. Utilizing a valve-regulated recombination architecture, the module architecture balances rack density with predictable discharge performance, delivering stable capacity for localized IT aggregation points and industrial control systems. The design features pasted plates with engineered porosity and a flame-retardant polymer enclosure to ensure minimal maintenance and safe operation in enclosed environments. Units are delivered on ventilated pallets with shock-absorbing pads and include lot-specific capacity test certificates. Supply-readiness is managed through internal resistance (IR) logs and serialized traceability, addressing the procurement requirements of facility managers seeking verified energy storage assets with documented state-of-health (SoH) metrics for multi-site rollouts and institutional asset management.
The technical framework of the Exide Powersafe Battery 42ah utilize a series-connected plate stack where each cell is governed by an integrated pressure-relief valve. The structural reasoning for the pasted-plate design is to maintain a high active material surface area, which is vital for providing consistent discharge currents during moderate autonomy events (1-3 hours). Measurement physics rely on the stability of the AGM (Absorbed Glass Mat) separator; a failure in the plate compression—due to manufacturing variance or mechanical shock—results in "electrolyte bypass," where the electrochemical reaction is uneven across the plate. This failure mode manifests as a rapid loss of capacity and localized thermal gain, effectively decommissioning the battery bank during its first critical discharge. The module utilize high-grade lead-calcium grids specifically chosen for their low self-discharge rates. Quality consistency is managed through serialized internal resistance (IR) logs; a failure to match IR values within a string results in "voltage drift," where one block overcharges while another remains under-capacity, leading to a 30% reduction in total service life. Our manufacturing logic employs 100% OCV (Open Circuit Voltage) verification to ensure every module meets the low-impedance standards required for peak power delivery.
Operational efficiency is achieved through the module’s predictable recharge acceptance, allowing B2B facility managers to accurately model the time-to-readiness after a grid disturbance. functional performance centers on the unit’s thermal dynamics; in real operational scenarios, a failure to manage the "cabinet ambient temperature" leads to thermal runaway—a failure mode where the battery temperature rises during charging, resulting in container melting and fire hazards. The Powersafe 42ah series utilizes UL94-V0 flame-retardant enclosures to mitigate this risk. if the system detects a significant increase in internal impedance through periodic monitoring, the serialized data allow for targeted replacement before the entire string is decommissioned. A failure in the terminal connection—due to improper torque—leads to high-resistance contacts, manifesting as localized thermal hotspots upon site commissioning. Ventilation is critical; units should be installed with specified air gaps to allow for passive convection. By establishment of a documented baseline of capacity and IR, the operator effectively improves the facility's overall reliability, providing the logistical and technical security required for institutional asset registration and energy accounting audits.
Designed for medium-density IT racks, emergency medical systems, and industrial controller backup, the 42ah unit is configured for the logistical requirements of multimodal multi-site procurement. Units ship on palletized crates with shock-absorbing pads and moisture-barrier film to protect the terminal seals during sea freight. Failure to implement shock-mitigating packaging results in "micro-cracks" at the terminal-to-casing seal, leading to electrolyte creep and corrosion of the interconnect busbars. For international procurement, supply-readiness is supported through lot-specific test certificates and material declarations (EN 10204). Export-ready documentation include material safety data sheets (MSDS) and certificates of conformity to facilitate customs review and institutional asset registration. Packaging utilize acid-resistant liners to comply with hazardous material handling protocols (UN2800). OEM private-label arrangements are supported, allowing for custom labeling and pre-configured terminal sets to match specific fleet standards. This high-authority approach ensure the procurement team receives verified energy assets that meet the safety and performance standards of global manufacturing markets, providing the transparency required for large-scale energy infrastructure management.
Inclusive of all taxes
You Save: 0
Amritsar , India
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler
GST- 03abgcs0227d1zz