Inclusive of all taxes
The EATON 10KVA Online UPS without Batteries from Shakti Power Solutions Pvt Limited is a robust power backup solution designed for critical business applications requiring reliable and continuous power supply. This UPS comes equipped with a true online double conversion technology featuring an IGBT-based rectifier, ensuring minimal power interruptions and clean output power. Supporting a wide input voltage range of 100VAC to 300VAC, it provides stable output voltages options between 200V to 240V AC, suitable for diverse international standards. The device is generator compatible and operates efficiently with an active input power factor correction of 0.99, which optimizes energy consumption and reduces electrical wastage. Its compact dimensions (102x228x346 mm) and light weight (3.8 KG) make it suitable for space-constrained environments. With a double conversion efficiency exceeding 91% and ECO mode efficiency up to 98%, this UPS ensures significant energy savings without compromising performance. Designed to operate under a temperature range of 0~40°C at full load, it is ideal for business-critical operations requiring uninterrupted power. This product comes without batteries, allowing businesses to integrate their preferred battery systems based on specific runtime requirements. Overall, it is a high-efficiency, generator-compatible UPS specifically tailored for industrial and commercial power backup needs, ensuring stable and uninterrupted power delivery in fluctuating voltage conditions.
Key Features
| Features | Description |
|---|---|
| Power Capacity | 10KVA |
| Technology | True Online Double Conversion with IGBT-based Rectifier |
| Input Voltage Range | 100VAC - 300VAC (160~300VAC @ 100% load, derating to 50% @ 100VAC) |
| Output Voltage | 200/208/220/230/240 VAC |
| Configuration | 1 Phase IN - 1 Phase OUT |
| Efficiency | Double Conversion Efficiency >91%, ECO mode up to 98% |
| Power Factor | Active Input Power Factor Correction 0.99 |
| Operating Temperature | 0~40°C at 100% load |
| Dimensions (W x D x H) | 102 x 228 x 346 mm |
| Weight | 3.8 KG |
| Battery | Without Batteries (Battery integration required separately) |
| Compatibility | Generator compatible with wide input voltage window |
| Design | Robust design suitable for industrial and commercial environments |
| Availability | In Stock |
| Attributes | Description |
|---|---|
| Brand | EATON |
| Model Number | 9E-1KVA Online UPS Without Battery |
| Input Voltage | 100VAC to 300VAC |
| Output Voltage | 200/208/220/230/240 VAC |
| Phase Configuration | Single Phase In / Single Phase Out |
| Efficiency Rating | Double Conversion >91%, ECO mode up to 98% |
| Power Factor Correction | 0.99 |
| Operating Temperature Range | 0°C to 40°C |
| Dimensions (WxDxH) | 102 x 228 x 346 mm |
| Weight | 3.8 Kg |
| Battery Status | UPS without batteries |
| Compatibility | Generator compatible |
| Technology Type | IGBT based rectifier, True Online Double Conversion technology |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
Yes, this UPS unit is supplied without batteries to allow customers to select external battery banks as per their specific requirements.
Yes, the EATON 10KVA Online UPS is designed to be generator compatible and operates efficiently within a wide input voltage window.
The UPS delivers up to 98% efficiency in ECO mode, facilitating significant energy savings.
It supports a wide input voltage range from 160 to 300VAC at 100% load, derating to 50% load at 100VAC input.
Brand: shakti power solutions
Country Of Origin: India
EATON 10KVA ONLINE UPS WITHOUT BATTERIES is a specialized online double-conversion power module designed for integration with site-specific external battery banks. The architecture features a configurable charger and high-capacity inverter stage, tuned for compatibility with varied battery chemistries and Ampere-hour ratings. This "without batteries" chassis allows facility managers to specify centralized energy storage solutions or extended autonomy configurations without the logistical constraints of pre-installed cells. Units ship in reinforced crating for consolidated logistics, featuring configuration records and electrical test reports. Supply-readiness is managed through functional verification and full-load burn-in testing, addressing the requirements of institutional procurement teams seeking high-availability power with documented compliance for site acceptance and asset tracking within facility-level battery systems.
The technical framework of the EATON 10KVA ONLINE UPS WITHOUT BATTERIES utilizes a high-fidelity power stage where the energy storage interface is decoupled from the primary conversion logic. The structural reasoning for this design is to provide "energy flexibility"—by omitting the internal battery stack, the unit can handle larger external DC bus currents without localized thermal accumulation. measurement physics rely on a high-speed DSP that regulates the output frequency and voltage to within ±1% accuracy. A failure in the voltage regulation circuit—due to component drift or surge—leads to "waveform clipping," which can decommission the stability of sensitive clinical or laboratory hardware. The unit architecture employs a configurable multi-stage charger; a failure to match the charger’s boost/float settings to the external bank results in "electrolyte dry-out" or chronic sulfation—a failure mode that reduces backup capacity by 50% over a 12-month period. Quality consistency is managed through serialized test logs documenting the unit's regulation accuracy and harmonic rejection profile under full-rated load, ensuring a stable voltage baseline for critical distribution nodes. The internal chassis uses segregated airflow paths to maintain semiconductor temperature stability during high-rate charging events.
Operational efficiency is achieved through the UPS’s high input power factor and the ability to maintain continuous double-conversion delivery even under severe grid fluctuations. functional performance centers on the unit’s ability to stabilize the DC bus when paired with appropriately sized external battery banks. In real operational scenarios, a failure in the inrush current limiting circuit leads to contactor pitting or fuse blowing during the initial power-on sequence—effectively decommissioning the facility’s power protection. The unit utilizes soft-start circuitry to protect both the internal components and the facility's upstream breakers. Monitoring outputs report real-time DC bus levels and charger status, providing B2B facility managers with event-driven diagnostic logs. if the UPS detects an internal logic fault, it triggers an audible alarm and provides a "system status" signal via its digital interface, allowing for event-driven maintenance before a total loss of load occurs. This systematic approach ensure the unit serves as a reliable data source for energy management and safety-instrumented systems (SIS), providing the technical transparency required for institutional asset registration and facility-level maintenance audits.
Designed for medium-sized IT rooms, distributed plant feeds, and medical diagnostic circuits, the 10 kVA battery-less module is configured for the logistical requirements of multimodal procurement. Units ship in reinforced crates with internal rigid bracing and shock-mitigating foam to protect the internal inductors and capacitors from mechanical shock during road and sea transport. Failure to implement shock-mitigating packaging can lead to "chassis racking," which manifests as high-resistance joints and potential localized fires upon site commissioning. For international procurement, supply-readiness is supported through serialized performance logs and compliance declarations (CE/IEC). Export-ready documentation include unit configuration snapshots and installation checklists provided with each shipment to facilitate customs review and institutional asset registration. Packaging utilize moisture-barrier covers and desiccants to prevent finish degradation during maritime transit. OEM branding and custom faceplate options are available for system builders requiring branded power modules for their equipment skids. This high-authority approach ensures procurement teams receive verified, site-ready hardware that meet the rigorous performance and safety requirements of global manufacturing markets.
Inclusive of all taxes
You Save: 0
Amritsar , India
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler