• Key Features & Attributes
  • Ratings & Reviews
  • Know your Supplier
  • Product description from supplier

Eaton DX-RT 10kVA/10kW 3x1

Inclusive of all taxes

The Eaton DX-RT 10kVA/10kW 3x1 is an advanced, modular UPS solution designed specifically for mission-critical power backup in small to mid-sized data centers and enterprise applications. With a power capacity of 10kVA/10kW, this 3-phase plus neutral UPS unit delivers highly reliable, scalable, and efficient power protection to ensure continuous operation of essential IT equipment. The Eaton 93PR series from which DX-RT derives its core technology, boasts industry-leading efficiency and low total cost of ownership, making it a future-ready investment that adapts to evolving IT environments including cloud integration and increasing environmental standards. Its modular design facilitates easy scalability and maintenance without downtime, while comprehensive safety and resiliency features maximize system availability. Compact in size (603 x 1013 x 2050 mm), the unit fits well into constrained spaces in data centers or critical infrastructure setups. Backed by a 1-year warranty and ready to ship from Shakti Power Solutions Pvt Limited with a minimum order quantity of 1, the Eaton DX-RT 10kVA/10kW 3x1 unit represents a reliable, export-ready solution for businesses seeking efficiency, safety, and uptime in power management.

Key Features

Features Description
Power Capacity 10kVA / 10kW
Phase Configuration 3 Phase + Neutral
Modular Design Enables scalability and maintenance without downtime
Efficiency Industry-leading efficiency minimizes total cost of ownership
Dimensions 603 x 1013 x 2050 mm
Application Critical Power Backup for Data Centers and Mission Critical Applications
Warranty 1 Year
Availability In Stock with MOQ 1
Safety Features Robust safety mechanisms to ensure operational continuity
Resiliency Ensures maximum availability and business continuity
Attributes Description
Brand Eaton
Model Name/Number Eaton DX-RT 10kVA/10kW 3x1
Product Series Eaton 93PR UPS
Capacity Range (Series) 25-200 kW
Power Output 10kVA / 10kW
Phase 3 Phase + Neutral
Size/Dimensions (WxDxH) 603 x 1013 x 2050 mm
Usage/Application Critical Power Backup Solution
Warranty 1 Year
Availability In Stock
MOQ 1 Unit

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

Yes, the Eaton DX-RT 10kVA UPS features a modular design enabling easy scalability to higher capacities by adding additional modules without downtime.

Absolutely, the Eaton 93PR series on which DX-RT is based is designed to support modern IT environments including cloud and virtualization applications.

The unit includes multiple safety and redundancy mechanisms to protect against power disturbances, ensuring maximum availability and business continuity.

The Eaton DX-RT 10kVA/10kW includes a 1-year warranty; the nature of warranty services including on-site support can be confirmed with Shakti Power Solutions Pvt Limited.

The minimum order quantity is 1 unit, making it ideal for businesses of all sizes.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Brand: shakti power solutions

Country Of Origin: India

DX-RT 10 kVA/10 kW 3x1 UPS – Single-Phase Output, Three-Phase Input

DX-RT 10 kVA/10 kW UPS implements a 3x1 input configuration with single-phase output, suitable for sites where three-phase mains feed a single-phase critical load. The design uses active rectification and inverter control to maintain output stability under unbalanced input conditions.

Units are delivered crate-protected with unit serialisation, burn-in test reports, and commissioning checklists. Supply protocols accommodate staged deliveries and OEM/private-label integration into customer cabinets. Pre-shipment acceptance testing is standard for contract arrangements.

Key Features

  • 3x1 input, single-phase output → accepts three-phase mains while supplying single-phase loads with balanced draw.
  • 10 kVA/10 kW rating → direct mapping to both apparent and active power for load planning.
  • Active power factor correction → reduces upstream THD and improves mains compatibility.

Technical Attributes

  • Rated active power: 10 kW → selection parameter where real power consumption is constrained.
  • Input stage: three-phase rectifier with PFC → lowers input current distortion under varying loads.
  • Output regulation: ±1–2% voltage tolerance → supports sensitive electronics.
  • Monitoring: event logging and remote alarm outputs → supports facility management integration.

DX-RT 10 kVA/10 kW — Electrical Topology and Input Balancing

The DX-RT employs a three-phase rectifier front-end feeding a central DC link; an inverter synthesises the single-phase output waveform with tight regulation. Input balancing logic monitors phase currents and redistributes rectifier load to prevent overload on a single phase, maintaining system stability even with upstream imbalance.

Functional Performance & Operational Efficiency

The unit maintains output frequency and voltage during mains aberrations and supports automatic bypass for maintenance. Active PFC reduces harmonic injection into the facility supply, which is critical in installations with sensitive upstream equipment. Built-in diagnostics support scheduled preventative maintenance and reduce unscheduled downtime.

Application & Industry Deployment

Suited to manufacturing cells, small data closets, and process-control cabinets where three-phase mains must feed single-phase critical loads. The system supports documented acceptance tests and can be integrated into contract supply scopes requiring pre-commissioned, labelled assemblies.

Frequently Asked Questions

  • How does the 3x1 input protect against phase imbalance? The rectifier control distributes current across phases and triggers alarms when imbalance exceeds set thresholds.
  • What is the output regulation band? Voltage regulation is maintained within approximately ±1–2% under normal operating conditions.
  • Is there a bypass for maintenance? An automatic and manual bypass is provided to permit service without interrupting the load.
  • What diagnostic outputs are standard? Remote alarm contacts, event logs, and optional SNMP telemetry are available for system integration.
  • What tests accompany delivery? Pre-shipment burn-in and site acceptance test documentation are supplied with each unit.


Electrical Equipment And Supplies

Industrial Power Supplies

shakti power solutions

Eaton DX-RT 10kVA UPS

10kW 3 Phase UPS

Eaton 93PR UPS

Modular UPS 10kW

Critical Power Backup

Data Center UPS

Scalable UPS Solution

Business Continuity UPS

Eaton DX-RT 10kVA/10kW 3x1

Inclusive of all taxes

You Save: 0

Send Inquiry
shakti power solutions pvt limited

Amritsar , India

Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler

GST- 03abgcs0227d1zz

  • Secure
    Transaction

  • Day
    Dispatch

Report a problem with this product