• Key Features & Attributes
  • Ratings & Reviews
  • Know your Supplier
  • Product description from supplier

Creatinine Reagent Kit (Jaffe Modified Method) for Quantitative Determination

Brand: labgene

Inclusive of all taxes

The Creatinine Reagent Kit (Jaffe Modified Method) is a specialized in-vitro diagnostic reagent designed for the precise quantitative determination of creatinine levels in human serum, plasma, and urine samples. Leveraging the established Jaffe modified method, this kit facilitates the formation of a colored complex when creatinine reacts with picrate in an alkaline medium, allowing for accurate photometric measurement. Particularly essential for medical laboratories, hospitals, and clinical diagnostic centers, this reagent kit provides reliable data critical for evaluating renal function and diagnosing kidney diseases. The photometric system’s fixed-time kinetic method ensures rapid, reproducible results that are directly proportional to creatinine concentration. Furthermore, the kit supports assessments integral to calculating creatinine clearance, thereby aiding in the comprehensive evaluation of glomerular filtration rate (GFR). Its cost-effective nature and ease of use make it a preferred choice for high-throughput environments needing precise renal biomarker analysis.

Key Features

Features Description
Measurement Principle Jaffe Modified Method using picrate reaction in alkaline medium
Sample Types Supported Human serum, plasma, and urine
Detection Method Fixed-time kinetic photometric measurement
Application Quantitative determination of creatinine for renal function assessment
Accuracy High precision and reproducibility of results
Turnaround Time Rapid testing suitable for clinical environments
Kit Composition Includes reagents optimized for Jaffe reaction
Clinical Use Supports calculation of creatinine clearance and GFR
Cost Efficiency Economical reagent kit suitable for routine testing
Compatibility Designed for use with standard photometric analyzers
Attributes Description
Methodology Jaffe Modified Colorimetric Method
Reaction Medium Alkaline solution with picrate
Sample Volume Required Typically 10-20 µL per test (subject to analyzer specifications)
Test Type In-vitro diagnostic reagent kit
Storage Conditions Store at 2-8°C, avoid freezing
Shelf Life 12 months from manufacturing date if stored properly
Reagent Stability After Opening Stable for up to 30 days when refrigerated
Intended Users Clinical laboratories and diagnostic centers
Calibration Requires external calibration with standard creatinine controls
Measurement Range Typically 0.1 to 20 mg/dL (dependent on analyzer settings)

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

Yes, the kit is designed to be fully compatible with standard photometric analyzers commonly used in clinical and diagnostic laboratories for automated processing.

Absolutely, the reagent kit supports quantitative analysis in human serum, plasma, and urine samples, covering the primary biological fluids used for renal function assessment.

Accuracy is optimized by following manufacturer instructions, utilizing proper sample volumes, calibrating the photometric equipment with standard creatinine controls, and maintaining reagent and sample storage conditions.

The fixed-time kinetic method enables a rapid and reproducible measurement by quantifying the rate of colored complex formation at a predetermined time point, reducing variability compared to endpoint assays.

After opening, the reagents should be refrigerated at 2-8°C and are stable for up to 30 days. Avoid repeated freeze-thaw cycles to maintain reagent integrity.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Brand: labgene

Country Of Origin: India

This is an in-vitro diagnostic (IVD) reagent kit for the quantitative determination of creatinine in human serum, plasma, and urine samples on a photometric system. The kit utilizes the Jaffe modified method, where creatinine reacts with picrate in an alkaline medium to form a colored complex. Measuring creatinine levels is crucial for estimating renal function and detecting kidney diseases.

Creatinine is a waste product filtered by the kidneys. Its concentration in blood and serum is typically stable in a healthy individual, so an increase in these levels indicates decreased excretion and, consequently, impaired kidney function. Measuring creatinine concentration is a reliable way to estimate and monitor renal function. The Creatinine Reagent Kit is based on the Jaffe modified method, a widely used and cost-effective technique. In this reaction, creatinine reacts with picrate in an alkaline solution to produce a colored complex. The rate of formation of this complex is measured photometrically and is directly proportional to the creatinine concentration in the sample. This fixed-time kinetic method allows for a rapid and accurate assessment of kidney health, making it an essential tool for hospitals, clinics, and diagnostic laboratories. The test is also used to calculate creatinine clearance, a more comprehensive measure of glomerular filtration rate (GFR).





labgene

Creatinine Reagent Kit

Jaffe Modified Method

Renal Function Test Kit

Quantitative Creatinine Assay

Photometric Creatinine Measurement

Kidney Function Diagnostic Reagent

Serum Creatinine Test

Urine Creatinine Assay

Creatinine Clearance Reagent

Creatinine Reagent Kit (Jaffe Modified Method) for Quantitative Determination

Brand: labgene

Inclusive of all taxes

You Save: 0

Send Inquiry
labgene bio-tech private limited

Mahesana , India

Manufacturer, Brand Owner, Exporter, Startup

  • Secure
    Transaction

  • Free
    Delivery

  • Day
    Dispatch

Report a problem with this product