MINILEC WLC D1 Water Level Controller

Inclusive of all taxes

The MINILEC WLC D1 Water Level Controller is a highly reliable and versatile device designed for precise monitoring and control of liquid levels using electrode sensors. Engineered for industrial and commercial applications, this controller supports a wide range of auxiliary supply voltages from 24 VAC/DC up to 440 V AC with ±10% tolerance and operates efficiently at both 50 Hz and 60 Hz frequencies. Equipped with a timing relay logic for enhanced control accuracy, the WLC D1 features a single changeover (1 CO) output contact, enabling seamless integration with pump and valve control systems. It accommodates up to three electrode sensors, offering flexibility for varied tank configurations and liquid types. Sensitivity is adjustable from 1K to 200K ohms, allowing precise calibration to specific installation environments and conductivity levels. The device boasts a fast trip time delay of less than 1 second to ensure timely response to level changes. Compactly designed with overall dimensions of 76 x 30.5 x 117.5 mm and lightweight construction (300 grams for the unit, 50 grams per sensor), it supports convenient DIN rail mounting (35 mm) with 68 mm center-to-center mounting points. The robust design and flexible features make the MINILEC WLC D1 an ideal solution for automated water level management in industrial tanks, water treatment plants, and process control systems.

Key Features

Features Description
Auxiliary Supply Voltage Range 24 VAC/DC to 100-120/220-240/380-440 V AC ± 10%, 50/60 Hz
Output Contact Type 1 Changeover (1 CO)
Number of Electrode Sensors Supported 3
Adjustable Sensitivity 1K - 200K Ohms
Trip Time Delay Less than 1 second
Unit Weight 300 grams
Sensor Weight 50 grams each
Overall Dimensions (L x W x D) 76 x 30.5 x 117.5 mm
Mounting 68 mm center-to-center / 35 mm DIN rail mounting
Timing Relay Logic Integrated for precise control
Attributes Description
Auxiliary Supply 24 VAC/DC / 100-120 V AC / 220-240 V AC / 380-440 V AC ± 10%
Frequency 50/60 Hz
Output Contacts 1 Changeover (1 CO)
Input Sensors 3 Electrodes
Sensitivity Range Adjustable from 1K to 200K Ohms
Trip Time Delay Less than 1 second
Unit Weight 300 g
Sensor Weight 50 g each
Unit Dimensions (L x W x D) 76 x 30.5 x 117.5 mm
Mounting Type DIN rail 35 mm / 68 mm center-to-center

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

The MINILEC WLC D1 supports a wide auxiliary supply voltage range from 24 VAC/DC to 100-120 V AC, 220-240 V AC, and 380-440 V AC with a ±10% tolerance, ensuring compatibility with various industrial power infrastructures and global electrical standards.

The adjustable sensitivity allows calibration of the controller to accurately detect liquid levels regardless of varying conductivity or composition of liquids, enabling precise operation in diverse applications such as water, oils, or chemical solutions.

A trip time delay under 1 second ensures rapid response to changes in liquid levels, preventing equipment damage or overflow by triggering immediate control actions such as pump shutdown or valve closure.

Yes, the unit is designed for easy installation on standard 35 mm DIN rails with mounting holes spaced 68 mm center-to-center, facilitating compatibility with industrial control panels.

The controller supports up to three electrode sensors, enabling multi-point liquid level detection for applications requiring monitoring of different fill levels or threshold points.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Brand: a s enterprises

Country Of Origin: India

Liquid Level Controllers WLC D1


Technical Data

WLC D1 - Timing-Relay logic Diagram

Auxilliary Supply

Auxilliary Supply24 VAC/DC/100-120/220-240/380-440 V AC ± 10%, 50 / 60 Hz

Output Contacts




Auxilliary Supply

Auxilliary Supply24 VAC/DC/100-120/220-240/380-440 V AC ± 10%, 50 / 60 Hz

Output Contacts

Output Contacts1 CO

Input Sensors

Input Sensors3 Electrodes

Sensitivity

Sensitivity1K - 200 K (adjustable)

Trip Time Delay

Trip Time DelayLess than 1 sec


Weight

Unit300 gms.

Sensor (each)50 gms.


Dimensions (mm)Unit

Overall (L x W x D)76 x 30.5 x 117.5

Mounting (L x W)68 mm centre to centre / 35 mm rail mounting





Testing Instrument And Equipment

Test Instruments

Water Meters

a s enterprises

MINILEC WLC D1

Water Level Controller

Liquid Level Controller

Electrode Sensor Water Control

Industrial Water Level Monitor

Timing Relay Water Controller

Adjustable Sensitivity Water Controller

DIN Rail Water Level Controller

MINILEC WLC D1 Water Level Controller

Inclusive of all taxes

You Save: 0

Send Inquiry
a s enterprises

Surat , India

Manufacturer, Contractor, Brand Owner, Distributor, Exporter, Importer, Wholesaler, Women Entrepreneur

  • Secure
    Transaction

  • Free
    Delivery

  • Day
    Dispatch

Report a problem with this product