DK32/34 - Variable area flowmeter for low liquid and gas flows

Inclusive of all taxes

The DK32/34 Variable Area Flowmeter is expertly designed for precise measurement of low liquid and gas flows, ideal for sample flow monitoring and fine metering in various industrial applications. Featuring a borosilicate glass measuring tube and high-grade gaskets such as EPDM, PTFE, and perfluoroelastomer rubber, this flowmeter ensures durability and chemical resistance. With integrated high-quality needle valves and available in configurations including stainless steel, brass, or PVDF fittings, it offers versatility for diverse process requirements. The device supports low flow rates starting from as little as 0.04 l/h or 0.1 GPH, suited to operate efficiently within -5 to +100°C temperature range and up to 10 barg (145 psig) pressure. The DK32/34 delivers reliable measurements with a maximum error margin between ±1% to ±4% of full scale, complying with VDI/VDE 3513-2 standards. Its cost-effective, low-maintenance design operates without auxiliary power and incorporates options for analogue scale, valve control, and limit switches, making it suitable for Safety Instrumented Systems with SIL 2 and SIL 3 compliance in redundant configurations. Precision, reliability, and compliance make DK32/34 an optimal choice for industry professionals seeking accurate low flow measurement solutions.

Key Features

Features Description
Measurement Principle Variable area float
Measuring Tube Material Borosilicate glass
Suitable Media Liquids and gases
Flow Range From ≥0.04 l/h (liquids) or ≥0.1 GPH (gas)
Operating Temperature -5 to +100°C (23 to 212°F)
Maximum Pressure Up to 10 barg / 145 psig
Gasket Materials EPDM, PTFE, Perfluoroelastomer rubber
Fitting Materials Stainless steel, brass, PVDF
Accuracy ±1% to ±4% of full scale (VDI/VDE 3513-2 compliant)
Power Requirement No auxiliary power needed
Integrated Valve High-quality needle valve
Compliance SIL 2 standard, SIL 3 (redundant 1oo2 design)
Thread Options G and NPT threads, others on request
Output Options Discrete limit switch outputs available
MOQ 1 unit
Attributes Description
Product Model DK32/34
Flow Measurement Type Variable area flowmeter
Minimum Liquid Flow Rate ≥0.04 l/h
Minimum Gas Flow Rate ≥0.1 GPH
Measuring Tube Borosilicate glass
Gasket Materials EPDM, PTFE, Perfluoroelastomer rubber
Fitting Options Stainless steel, brass, PVDF
Operating Temperature Range -5 to +100°C (23 to 212°F)
Maximum Pressure 10 barg (145 psig)
Measurement Accuracy ±1% / ±2.5% / ±4% per VDI/VDE 3513-2
Power Requirement None (low-cost, no auxiliary power)
Valve Type Integrated needle valve in foot or head piece
Thread Types G and NPT threads (others on request)
Safety Compliance SIL 2, SIL 3 in redundant 1oo2 design
Available Outputs Discrete limit switches
MOQ 1 unit
Availability In stock

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

Yes, the DK32/34 is designed specifically for measuring both low flow liquids and gases with high accuracy, utilizing a variable area float principle.

Standard G and NPT threaded connections are available, with other thread types available upon request to match client piping requirements.

Yes, the DK32/34 is certified for SIL 2 applications and can be used in SIL 3 applications in redundant 1oo2 configurations, making it suitable for critical safety systems.

The maximum operating pressure is 10 barg (145 psig), suitable for many industrial low flow applications.

No, this flowmeter operates on a low-cost measuring principle that requires no auxiliary power.

Yes, the DK32/34 offers discrete limit switch outputs that can be integrated into process control and monitoring systems.

The device uses EPDM, PTFE, and perfluoroelastomer rubber gaskets offering excellent chemical resistance and sealing performance suited for various media.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Brand: shakti power solutions

Country Of Origin: India

DK32/34 Variable Area Flowmeter – Float-Type Meter for Low Flows

DK32/34 Variable Area Flowmeter is a float-based measurement instrument designed for the precise volumetric metering of low liquid and gas flows in process and laboratory applications. Utilizing a tapered tube architecture and calibrated float, the unit delivers a direct visual readout without the requirement for external power. The design emphasizes mechanical simplicity and low-maintenance operation, featuring clear scale markings in engineering units to facilitate immediate process monitoring. Prepared for volume orders, units are supplied with factory calibration reports and batch-specific QA documentation. Supply-readiness is managed through factory-verified scale accuracy and pressure testing, addressing the requirements of facility managers seeking dependable, cost-effective metering for laboratory supply lines and chemical dosing. Packaging utilizes foam-molded inserts and moisture-barrier film to protect the tapered tube and internal float during transit.

Key Features

  • Tapered tube float technology → provides an instantaneous visual volumetric reading using process energy alone, eliminating the risk of electronic failure in critical bypass or dosing lines.
  • Engineering-unit scale markings → features factory-applied markings for specific liquids or gases to simplify on-site process verification and reduce reading errors.
  • Low-maintenance mechanical layout → utilize a simple vertical-tube design with non-clogging floats to extend service life and simplify periodic site maintenance.

Technical Attributes

  • Flow Range: Low-flow calibrated → selection parameter matched to specific process demand for high-fidelity accuracy.
  • Wetted Materials: Selectable Alloys/Polymers → selection based on the chemical compatibility and density of the process fluid.
  • Accuracy Class: Model-specific → selection parameter for ensuring compliance with facility-level process control standards.
  • Logistics: Foam-cradled Packaging → ensures the structural integrity of the tapered tube during multimodal transport and staging.

Meter Construction and Material selection Logic of the DK32/34

The technical framework of the DK32/34 Variable Area Flowmeter utilizes a tapered transparent or metallic tube where a precision-machined float moves vertically in response to flow velocity. The structural reasoning for the tapered geometry is to create a varying annular area—as flow increases, the float rises to a position where the upward hydraulic forces balance the gravitational mass of the float. measurement physics rely on the stability of the float's density and the tube's internal profile; a failure in the tube's concentricity—due to manufacturing variance—results in "float sticking" and erratic flow readouts, effectively decommissioning the measurement point. Quality consistency is managed through serialized batch resistance measurements and factory-performed wet calibration against reference standards. The materials for the tube and float are selected to match the process fluid's specific gravity; if the density is miscalculated, the float will remain at the base or the top of the tube, decommissioning the measurement node. Our manufacturing logic employs specialized polishing of the internal bore to minimize frictional lag and ensure high measurement repeatability.

Functional Performance and Operational Efficiency in Laboratory Lines

Operational efficiency is achieved through the unit’s ability to provide immediate flow confirmation without requiring digital integration or external supply, an essential operational standard for remote laboratory suites or unconditioned utility bays. functional performance centers on the unit’s response at low Reynolds numbers; variable-area technology remains stable in flow regimes where electromagnetic or ultrasonic meters may decommissioning. In a real operational scenario, a failure to manage "pulsation" in the process line—due to pump vibration—leads to float oscillation, making it difficult to obtain an accurate reading. To mitigate this, the DK32/34 series utilize optional magnetic or pneumatic damping systems. if the tube becomes obscured by process fallout—due to scale or grease buildup—the visual indication decommissions; the unit utilize accessible clean-out ports to allow for maintenance without system shutdown. By provides a stable and traceable signal, the meter improves the overall reliability of localized equipment monitoring, ensuring that thermal or chemical thresholds are accurately tracked for safety interlocks.

Institutional Deployment and Logistical Readiness for instrument Fleets

Designed for laboratory supply lines, fuel metering for burners, and process bypass streams, the DK32/34 is configured for the logistical requirements of multimodal procurement. Units ship in foam-lined trays with moisture-barrier film to protect the sensitive internal float and scale markings during transport. Failure to implement shock-mitigating packaging can lead to "tube cracking" or float misalignment, which decommissions the unit's calibration upon arrival. For international procurement, supply-readiness is supported by lot-specific calibration certificates and material declarations (ISO/CE). Export-ready documentation include unit configuration snapshots and installation guides provided with each consignment to facilitate institutional asset registration. Packaging utilize humidity-control liners to prevent finish degradation of the metal casings during maritime freight. OEM branding and custom faceplate options are available for system builders requiring branded instrumentation for their equipment skids. This high-authority approach ensure procurement teams receive verified hardware that meet the performance and safety requirements of global markets, providing the technical transparency required for large-scale energy infrastructure rollouts.

Frequently Asked Questions

  • How is the meter calibrated for different fluids? Each unit is calibrated against reference flows of the specified liquid or gas and supplied with a custom scale certificate.
  • Can it operate without electrical power? Yes; the variable-area principle is purely mechanical, making it ideal for safety-critical zones and power-loss scenarios.
  • What maintenance is required for the float? Periodic visual inspection and cleaning of the internal bore are recommended where particulate or fouling media is present.
  • How is moisture risk managed during shipping? Packaging includes moisture-barrier film and desiccant pouches inside a foam-lined carton.
  • What documentation accompanies each unit? Every shipment includes a factory calibration report, lot inspection certificate, and installation instructions.


Testing Instrument And Equipment

Test Instruments

Flow Meters

shakti power solutions

Variable Area Flowmeter

Low Flow Flowmeter

Borosilicate Glass Flowmeter

Needle Valve Flowmeter

Low Liquid Flow Measurement

Low Gas Flow Measurement

SIL 2 Flowmeter

SIL 3 Flowmeter

Industrial Flowmeter

DK32/34 Flowmeter

DK32/34 - Variable area flowmeter for low liquid and gas flows