Inclusive of all taxes
The DK32/34 Variable Area Flowmeter is expertly designed for precise measurement of low liquid and gas flows, ideal for sample flow monitoring and fine metering in various industrial applications. Featuring a borosilicate glass measuring tube and high-grade gaskets such as EPDM, PTFE, and perfluoroelastomer rubber, this flowmeter ensures durability and chemical resistance. With integrated high-quality needle valves and available in configurations including stainless steel, brass, or PVDF fittings, it offers versatility for diverse process requirements. The device supports low flow rates starting from as little as 0.04 l/h or 0.1 GPH, suited to operate efficiently within -5 to +100°C temperature range and up to 10 barg (145 psig) pressure. The DK32/34 delivers reliable measurements with a maximum error margin between ±1% to ±4% of full scale, complying with VDI/VDE 3513-2 standards. Its cost-effective, low-maintenance design operates without auxiliary power and incorporates options for analogue scale, valve control, and limit switches, making it suitable for Safety Instrumented Systems with SIL 2 and SIL 3 compliance in redundant configurations. Precision, reliability, and compliance make DK32/34 an optimal choice for industry professionals seeking accurate low flow measurement solutions.
Key Features
| Features | Description |
|---|---|
| Measurement Principle | Variable area float |
| Measuring Tube Material | Borosilicate glass |
| Suitable Media | Liquids and gases |
| Flow Range | From ≥0.04 l/h (liquids) or ≥0.1 GPH (gas) |
| Operating Temperature | -5 to +100°C (23 to 212°F) |
| Maximum Pressure | Up to 10 barg / 145 psig |
| Gasket Materials | EPDM, PTFE, Perfluoroelastomer rubber |
| Fitting Materials | Stainless steel, brass, PVDF |
| Accuracy | ±1% to ±4% of full scale (VDI/VDE 3513-2 compliant) |
| Power Requirement | No auxiliary power needed |
| Integrated Valve | High-quality needle valve |
| Compliance | SIL 2 standard, SIL 3 (redundant 1oo2 design) |
| Thread Options | G and NPT threads, others on request |
| Output Options | Discrete limit switch outputs available |
| MOQ | 1 unit |
| Attributes | Description |
|---|---|
| Product Model | DK32/34 |
| Flow Measurement Type | Variable area flowmeter |
| Minimum Liquid Flow Rate | ≥0.04 l/h |
| Minimum Gas Flow Rate | ≥0.1 GPH |
| Measuring Tube | Borosilicate glass |
| Gasket Materials | EPDM, PTFE, Perfluoroelastomer rubber |
| Fitting Options | Stainless steel, brass, PVDF |
| Operating Temperature Range | -5 to +100°C (23 to 212°F) |
| Maximum Pressure | 10 barg (145 psig) |
| Measurement Accuracy | ±1% / ±2.5% / ±4% per VDI/VDE 3513-2 |
| Power Requirement | None (low-cost, no auxiliary power) |
| Valve Type | Integrated needle valve in foot or head piece |
| Thread Types | G and NPT threads (others on request) |
| Safety Compliance | SIL 2, SIL 3 in redundant 1oo2 design |
| Available Outputs | Discrete limit switches |
| MOQ | 1 unit |
| Availability | In stock |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
Yes, the DK32/34 is designed specifically for measuring both low flow liquids and gases with high accuracy, utilizing a variable area float principle.
Standard G and NPT threaded connections are available, with other thread types available upon request to match client piping requirements.
Yes, the DK32/34 is certified for SIL 2 applications and can be used in SIL 3 applications in redundant 1oo2 configurations, making it suitable for critical safety systems.
The maximum operating pressure is 10 barg (145 psig), suitable for many industrial low flow applications.
No, this flowmeter operates on a low-cost measuring principle that requires no auxiliary power.
Yes, the DK32/34 offers discrete limit switch outputs that can be integrated into process control and monitoring systems.
The device uses EPDM, PTFE, and perfluoroelastomer rubber gaskets offering excellent chemical resistance and sealing performance suited for various media.
Brand: shakti power solutions
Country Of Origin: India
DK32/34 Variable Area Flowmeter is a float-based measurement instrument designed for the precise volumetric metering of low liquid and gas flows in process and laboratory applications. Utilizing a tapered tube architecture and calibrated float, the unit delivers a direct visual readout without the requirement for external power. The design emphasizes mechanical simplicity and low-maintenance operation, featuring clear scale markings in engineering units to facilitate immediate process monitoring. Prepared for volume orders, units are supplied with factory calibration reports and batch-specific QA documentation. Supply-readiness is managed through factory-verified scale accuracy and pressure testing, addressing the requirements of facility managers seeking dependable, cost-effective metering for laboratory supply lines and chemical dosing. Packaging utilizes foam-molded inserts and moisture-barrier film to protect the tapered tube and internal float during transit.
The technical framework of the DK32/34 Variable Area Flowmeter utilizes a tapered transparent or metallic tube where a precision-machined float moves vertically in response to flow velocity. The structural reasoning for the tapered geometry is to create a varying annular area—as flow increases, the float rises to a position where the upward hydraulic forces balance the gravitational mass of the float. measurement physics rely on the stability of the float's density and the tube's internal profile; a failure in the tube's concentricity—due to manufacturing variance—results in "float sticking" and erratic flow readouts, effectively decommissioning the measurement point. Quality consistency is managed through serialized batch resistance measurements and factory-performed wet calibration against reference standards. The materials for the tube and float are selected to match the process fluid's specific gravity; if the density is miscalculated, the float will remain at the base or the top of the tube, decommissioning the measurement node. Our manufacturing logic employs specialized polishing of the internal bore to minimize frictional lag and ensure high measurement repeatability.
Operational efficiency is achieved through the unit’s ability to provide immediate flow confirmation without requiring digital integration or external supply, an essential operational standard for remote laboratory suites or unconditioned utility bays. functional performance centers on the unit’s response at low Reynolds numbers; variable-area technology remains stable in flow regimes where electromagnetic or ultrasonic meters may decommissioning. In a real operational scenario, a failure to manage "pulsation" in the process line—due to pump vibration—leads to float oscillation, making it difficult to obtain an accurate reading. To mitigate this, the DK32/34 series utilize optional magnetic or pneumatic damping systems. if the tube becomes obscured by process fallout—due to scale or grease buildup—the visual indication decommissions; the unit utilize accessible clean-out ports to allow for maintenance without system shutdown. By provides a stable and traceable signal, the meter improves the overall reliability of localized equipment monitoring, ensuring that thermal or chemical thresholds are accurately tracked for safety interlocks.
Designed for laboratory supply lines, fuel metering for burners, and process bypass streams, the DK32/34 is configured for the logistical requirements of multimodal procurement. Units ship in foam-lined trays with moisture-barrier film to protect the sensitive internal float and scale markings during transport. Failure to implement shock-mitigating packaging can lead to "tube cracking" or float misalignment, which decommissions the unit's calibration upon arrival. For international procurement, supply-readiness is supported by lot-specific calibration certificates and material declarations (ISO/CE). Export-ready documentation include unit configuration snapshots and installation guides provided with each consignment to facilitate institutional asset registration. Packaging utilize humidity-control liners to prevent finish degradation of the metal casings during maritime freight. OEM branding and custom faceplate options are available for system builders requiring branded instrumentation for their equipment skids. This high-authority approach ensure procurement teams receive verified hardware that meet the performance and safety requirements of global markets, providing the technical transparency required for large-scale energy infrastructure rollouts.
Inclusive of all taxes
You Save: 0
Amritsar , India
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler
GST- 03abgcs0227d1zz