• Key Features & Attributes
  • Ratings & Reviews
  • Know your Supplier
  • Product description from supplier

Tablet Disintegration Tester - Single Drive

Inclusive of all taxes

The Tablet Disintegration Tester - Single Drive is a precision instrument designed specifically for quality and production control of normal plain coated tablets and gelatin capsules. Featuring a 7-inch color high-resolution capacitive touch screen with an interactive user interface, it adheres strictly to USP, IP, BP, and other pharmacopoeia standards. The device supports programmable temperature and time controls to suit varied testing protocols and includes innovative features such as laser-marked basket assembly to identify disintegrated tablet positions, ensuring accurate test tracking and compliance. The molded clear acrylic water bath with illumination enhances visibility during tests, while the auto park-out function safely secures the basket after run completion. Dual buffer disintegration testing, audible low water level alarms, and external temperature sensors for individual beakers extend operational safety and reliability. With PC connectivity and EDC 21 software support, test data can be downloaded, previewed, and stored efficiently, backed up on an SD card with restore capability. The unit’s robust design features a single drive mechanism for two baskets with individual timers, precise dip speed and stroke length conforming to pharmacopoeia requirements, and programmable time up to 99:59 (HH:MM). Its user management supports up to 50 users with customizable rights and stores up to 100 test methods. Suitable for indoor operation in varied environmental conditions, this Tablet Disintegration Tester offers comprehensive functionalities tailored for stringent pharmaceutical testing environments, ensuring productivity, accuracy, and regulatory compliance.

Key Features

Features Description
Display 7” color high-resolution capacitive touch screen with interactive software
Compliance Meets USP, IP, BP and other pharmacopoeia specifications
Test Types Normal plain coated tablets and gelatin capsules quality control
Programmable Settings Temperature and time adjustable up to 99:59 (HH:MM)
Basket Identification Laser marked numbers on basket assembly to identify disintegrated tablet position
Water Bath Molded clear acrylic with illumination for better visibility
Safety Features Auto park-out basket, audible low water level alarm with display indication
Data Management PC-based data download via RS232C, EDC 21 software compatible, SD card backup and restore
User Management 1 admin and 50 users with multiple rights selection
Test Capacity Single drive for 2 baskets with individual timer
Hardware Specs Dip speed 30 ±1 DPM, Stroke length 55 ±2 mm, water bath temp range ambient +5 to 55°C
Connectivity Centronics Parallel Port for printer connectivity, RS232C for PC
Included Accessories 2 baskets (6 tubes each), 12 fluted discs, 2 temperature sensors, 2 glass beakers (1000 ml)
Attributes Description
Drive Type Single drive
Dip Speed 30 ± 1 DPM (Dips Per Minute)
Stroke Length 55 ± 2 mm
Water Bath Temperature Range Ambient +5 to 55°C
Temperature Accuracy ± 0.2°C
Water Bath Circulation Immersion pump
Beaker Volume 1000 ml
Basket Capacity 2 baskets with 6 test positions each (10 mesh USP Type A standard); optional baskets and mesh sizes available
Fluted Disks 6 disks per basket for USP type A
Test Mode Programmable time up to 99:59 (HH:MM) with display format 99:59:59
User Management 1 admin and 50 users with customizable rights
Test Methods Capacity Up to 100 test methods storable
Report Storage Built-in SD card
Printer Interface Centronics parallel port for dot matrix or deskjet printers
PC Connectivity RS232C port for data download to PC
Power Requirements 230 VAC / 50 Hz, 325 W
Operating Environment Indoor use, ambient temperature up to 45°C, humidity 20-80%, altitude up to 2000m
Dimensions 330 x 345 x 580 mm (W x D x H approx.)
Weight Approx. 22 kg
Included Accessories 2 baskets (6 tubes each), 12 fluted discs, 2 temperature sensors, 2 glass beakers (1000 ml)

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

Yes, the Tablet Disintegration Tester single drive is specifically designed to perform quality control tests on normal plain coated tablets as well as gelatin capsules, allowing versatility in pharmaceutical production testing.

The laser marked numbers on the basket assembly help accurately identify the position of each disintegrated tablet during testing, minimizing errors in result logging and enhancing traceability.

It offers PC-based data download using EDC 21 software, preview of results prior to printing, customizable report files, SD card backup and restore features for secure and efficient data management.

The provision to lock individual tablet disintegration time by using an external keyboard with basket numbers is available as an optional feature.

The unit includes an audible low water level alarm with display indication, auto park out facility for baskets after test completion, and external temperature sensors for individual beakers to ensure safe and reliable operations.

The tester should be operated indoors within ambient temperatures up to 45°C, with humidity maintained between 20% to 80%, and at altitudes up to 2000 meters for reliable performance.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Country Of Origin: India

Features:

• 7” Color High resolution display with touch screen interface & user interactive software.

• Meets current specification of USP, IP, BP and other Pharmacopoeias

• Specifically designed for use in the quality and production control of normal plain coated tablets & gelatin capsules

• Programmable Temperature & Time

• Provision to identify the position of disintegrated tablet with laser marked numbers on basket assembly

• Provision to lock individual tablet disintegration time by using external key board with basket numbers (Optional)

• Molded clear acrylic water bath with illumination for better visibility

• Auto Park out facility for basket after run completion

• Capability for dual buffer disintegration test

• Audible, low water level alarm with indication on display for safety

• External temperature sensors available for individual beaker

• PC Based Data downloading facility using EDC 21 software

• Customizable Report File

• Preview Result data before printing

• Auto Resume facility to continue the run in case power failure

• Data backup to SD card & restore facility available

• User can easily adjust brightness of screen


Specifications:

• Drive: Single Drive for 2 baskets with individual timer

• Dip Speed: 30, ±1 DPM

• Stroke length: 55, ± 2mm

• Waterbath temperature range: Ambient +5 to 55°C

• Waterbath temperature accuracy: ± 0.2°C

• Waterbath circulation: Immersion Pump

• Beaker volume: 1000 ml

• Basket: 2X6 test positions (10 mesh) USP type A/ (Optional 40 mesh)

             2X3test positions (10 mesh) USP type B/ Bolus 3 Basket

             2X1test positions (10 mesh) USP type B/ Bolus 1 Basket

• Fluted Disk: 6 numbers in each basket for USP type A

• Test Mode: Programmable Time up to 99:59 (HH:MM) Display Format 99:59:59

• Display: 7’’ Capacitive touch screen colour display

• User management: 1 admin ,50 users with multiple rights selection

• Number of Methods: 100 test methods

• Report storage: Built-in SD Card

• Printer connectivity: Centronics Parallel Port for Dot matrix/ desk jet printer

• Serial Interface: RS232C-2 for PC Connectivity for data download

• Power Requirement: 230VAC / 50 Hz, 325 W

• Environmental Operating conditions: a) Operation Indoor

                                                           b) Temperature Ambient to 45°C

                                                           c) Humidity 20% to 80%

                                                           d) Altitude up to 2000m

• Dimension (Approx.): 330 X 345 X 580 mm (W X D X H)

• Shipping Weight (Approx.): 22 kg.


Comes with following items:

• Baskets of 6 tubes each 2 Nos

• Fluted Disc 12 Nos

• Temperature Sensors 2 Nos

• Glass Beakers 1000ml 2 Nos.


Testing Instrument And Equipment

Testing Equipment

Tablet Disintegration Tester

Single Drive Disintegration Tester

Pharmaceutical Tablet Tester

USP Disintegration Tester

Capsule Disintegration Tester

Quality Control Tester

Tablet Dissolution Tester

Programmable Disintegration Tester

Tablet Disintegration Tester - Single Drive

Inclusive of all taxes

You Save: 0

Send Inquiry
vinca labtech and scientific solutions private lim

Indore , India

Distributor, Exporter, Wholesaler

GST- 23aajcv4134a1zt

  • Secure
    Transaction

  • Free
    Delivery

  • Day
    Dispatch

Report a problem with this product