Ro Components Industrial Membrane 4" SERIES

Inclusive of all taxes

The Ro Components Industrial Membrane 4" SERIES is a high-performance reverse osmosis membrane designed for industrial water purification applications. Engineered to operate under stringent conditions, this membrane delivers efficient desalination and contaminant removal from feed water with a remarkable recovery rate of 15% per single element. It is tested rigorously at 150 psi testing pressure and 25°C with a 1500 ppm NaCl solution at pH 7.5 to ensure consistent performance and durability. The membrane supports a maximum working pressure of up to 600 psi (4.14 Mpa) and can handle feed water temperatures up to 45°C, making it suitable for a variety of industrial process water and wastewater treatment scenarios. The maximum feed water volume capacity is 16 gallons per minute (gpm), with a specific capacity of 8 gpm for the 4021 model variant. Ideal for continuous operations, this membrane accommodates a pH range from 3 to 10 during operation and a wider pH range from 2 to 12 for chemical cleaning procedures, ensuring extended membrane life and performance robustness. Additionally, it requires feed water with residual chlorine concentration lower than 0.1 ppm to prevent membrane degradation. Pressure drop limits are optimized for system integration, with a maximum pressure drop of 15 psi per single membrane element and 50 psi per vessel housing up to six membranes. The Ro Components Industrial Membrane 4" SERIES represents a reliable choice for manufacturers and industrial enterprises seeking to enhance their water purification capabilities efficiently and sustainably.

Key Features

Features Description
Membrane Diameter 4 inches
Testing Pressure 150 psi (1.03 Mpa)
Testing Solution Concentration 1500 ppm NaCl
Testing Solution Temperature 25°C
Testing Solution pH 7.5
Recovery Rate of Single Element 15%
Maximum Working Pressure 600 psi (4.14 Mpa)
Maximum Feed Water Temperature 45°C
Maximum Feed Water Volume 16 gpm (3.6 m³/h); 8 gpm for 4021 model
pH Range During Operation 3 - 10
pH Range During Chemical Cleaning 2 - 12
Residual Chlorine Concentration Limit <0.1 ppm
Max Pressure Drop (Single Element) 15 psi (0.1 Mpa)
Max Pressure Drop (Vessel with Six Membranes) 50 psi (0.34 Mpa)
Attributes Description
Membrane Type Industrial Reverse Osmosis Membrane
Membrane Series 4" SERIES
Material Polyamide Thin Film Composite
Max Operating Pressure 600 psi
Operating Temperature Range Up to 45°C
Feed Water Quality Requirements SDI ≤ 5, Residual Chlorine <0.1 ppm
Pressure Vessel Compatibility Supports vessels with up to six membranes
Recovery Rate 15% per element
Flow Rate Capacity 16 gpm general; 8 gpm for 4021 model
pH Operating Range 3-10 continuous; 2-12 during cleaning

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

The maximum feed water SDI recommended is 5 to ensure optimal membrane life and prevent fouling.

The membrane is designed to operate with residual chlorine concentrations in feed water less than 0.1 ppm to avoid membrane damage.

During continuous operation, the membrane tolerates a pH range of 3 to 10, while during chemical cleaning, it can withstand a wider pH range of 2 to 12.

The maximum permissible feed water temperature is 45°C for this membrane series.

The maximum pressure drop for a single membrane element is 15 psi (0.1 Mpa), and for a pressure vessel containing six membranes, it is 50 psi (0.34 Mpa).

The maximum feed water volume capacity is 16 gpm for the general membrane and 8 gpm specifically for the 4021 model.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Country Of Origin: India




Testing Conditions

Testing Pressure : 150 psi (1.03 Mpa)

Testing Solution Temperature : 25°C

Concentration of Testing Solution (NaCl) : 1500 ppm

pH value of Testing Solution : 7.5

Recovery Rate of Single Element : 15%

Max. Working Pressure : 600 psi (4.14 Mpa)

Max. Temperature of Feed water : 45°C

Max. Volume of Feed water  :16 gpm (3.6 m²³/h)
                                              : 8 gpm (for 4021)

Operation Limit & Conditions

Max. Feed water Sdi 15 : 5

pH Range of Feed water during Continuous Operation  : 3-10

pH Range of Feed Water during Chemical Cleaning : 2-12

Residual Chlorine Concentration of Feed Water : <0.1 ppm

Max. Pressure Drop of Single Membrane Element : 15 psi (0.1 Mpa)

Max. Pressure Drop of Single Pressure Vessel with Six RO Membranes : 50 psi (0.34 Mpa)





Machinery And Tools

Filter Supplies

Industrial RO Membrane

4 Inch RO Membrane

High-pressure Reverse Osmosis Membrane

Industrial Water Purification Membrane

RO Membrane 15% Recovery

Chemical Cleaning Compatible Membrane

Feed Water Treatment Membrane

600 Psi RO Membrane

Industrial Water Treatment Components

Ro Components Industrial Membrane 4" SERIES

Inclusive of all taxes

You Save: 0

Send Inquiry
lexcru water tech private limited

Ahmedabad , India

Manufacturer, Brand Owner, Distributor, Exporter, Wholesaler, Women Entrepreneur

  • Secure
    Transaction

  • Free
    Delivery

  • Day
    Dispatch

Report a problem with this product