The DSSE AWS Venus Fully Loaded Anaesthesia Workstation is a state-of-the-art, pneumatically driven and electronically controlled anesthesia delivery system designed for both adult and pediatric patients. Engineered to offer superior performance in a clinical setting, this workstation supports a semi-open, semi-closed, or closed anesthesia delivery system complemented by dual high-precision vaporizers compatible with Halothane, Isoflurane, and Sevoflurane. Featuring a user-friendly 7-inch TFT touchscreen interface, the ventilator supports multiple ventilation modes including VCMV, V-SIMV, PCMV, P-SIMV, PRVC, PSV, BAG, and a standby mode, allowing maximum flexibility for patient respiratory management. The system is equipped with advanced safety features such as low and high-pressure alarms, driving gas failure alerts, and backup ventilation modes to ensure patient safety under various clinical scenarios. Its robust construction includes a rust-proof epoxy-coated high-strength frame and integral pipeline attachments, making it ideal for hospital operating rooms and surgical centers aiming at efficient and reliable anesthesia delivery.
Key Features
| Features | Description |
|---|---|
| Application | Suitable for both Adult and Pediatric patients |
| Drive Mode | Pneumatically driven and electronically controlled |
| Anesthetic Vaporizers | Two high-precision vaporizers compatible with Halothane, Isoflurane, and Sevoflurane |
| Ventilation Modes | Supports VCMV, V-SIMV, PCMV, P-SIMV, PRVC, PSV, BAG, and Standby |
| Display | 7-inch TFT with Touch Screen Interface |
| Tidal Volume Range | 50 to 1500 ml |
| Respiratory Rate Range | 1 to 60 breaths per minute |
| Pressure Support | 5 to 40 cmH2O |
| Power Supply | 100-240V, 50/60Hz with < 50W consumption |
| Battery Backup | Lithium-ion battery providing up to 2 hours backup |
| Safety Features | Alarms for pressure, respiratory rate, minute volume, FIO2, patient activity, driving gas failure, and low battery |
| Fresh Gas Outlet Position | Located at front of frame for easy access |
| Rota Meter | Five tube flow meters with bobbin type for precise gas flow control |
| Absorber | Upgraded integrated twin large volume CO2 absorber with non-return valves |
| Frame | Rust-proof epoxy-coated, high-strength with pipeline attachments |
| Oxygen Flush | Adjustable 25L/min to 75L/min |
| Attributes | Description |
|---|---|
| Tidal Volume | 50 to 1500 ml |
| Respiratory Rate | 1 to 60 BPM |
| Inspiratory Time (Ti) | 0.2 to 8.0 seconds |
| I: E Ratio | 4:1 to 1:4 |
| Plateau Pressure | 0 to 50 cmH2O |
| Pressure Support Range | 5 to 40 cmH2O |
| Trigger Sensitivity | 0.5 to 5.0 cmH2O |
| PEEP Range | 1 to 30 cmH2O |
| Pressure Limit | 20 to 60 mBar |
| Backup Respiratory Rate | 6 to 60 BPM |
| Backup Modes | VCMV, V-SIMV, PCMV, P-SIMV, PRVC |
| Power Consumption | < 50W |
| Gas Source Pressure | O2: 0.25-0.65 MPa, N2O: 0.25-0.65 MPa, Air: 0.25-0.65 MPa |
| O2 Tube Flow Range | 0.1L/min to 15L/min |
| N2O Tube Flow Range | 0.1L/min to 12L/min |
| Air Tube Flow Range | 0.1L/min to 15L/min |
| Fresh Gas Outlet Location | Front of frame |
| Frame Material | Epoxy coated rust-proof high strength metal |
| Number of Vaporizers | Two, with select tec bar to mount |
| Battery Type | Lithium-ion with 2 hours backup |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
It supports multiple ventilation modes including VCMV, V-SIMV, PCMV, P-SIMV, PRVC, PSV, BAG, and Standby mode to provide comprehensive respiratory management options.
The workstation uses a lithium-ion battery providing up to 2 hours of continuous backup power to ensure uninterrupted operation during power failures.
Yes, it includes two high-precision vaporizers compatible with Halothane, Isoflurane, and Sevoflurane, allowing flexible anesthetic agent selection and delivery.
The system is equipped with alarms for low and high pressure, respiratory rate, minute volume, FIO2, active patient detection, driving gas failure, and low battery to ensure continuous patient safety.
Yes, the DSSE AWS Venus is designed for both adult and pediatric patients, with tidal volumes as low as 50 ml and respiratory rates of 1 to 60 BPM to accommodate smaller lung capacities.
It features an upgraded integrated twin large-volume CO2 absorber with non-return respiratory and expiratory valves to prevent gas backflow, enhancing safety and efficiency.
Brand: dsse
Country Of Origin: India
DSSE AWS Venus Fully Loaded-
TECHNICAL FEATURES
Application : Adult, Paediatric
Driven Mode : Pneumatically driven electronically controlled
Mode : Semi-open, Semi-closed or closed system
Anesthetic vaporizer: Two hgt precise vaporizers, Halothane /Isoflurane/Sevoflurane
Power supply : 100-240V, 50/60Hz
Power Consumption: < 50W Fresh gas outlet is in front of frame
ANESTHESIA VENTILATOR SPECIFICATION
Display : 7" TFT with Touch Screen
Mode of Operation : VCMV, V- SIMV, PCMV, P-SIMV, PRVC, PSV, BAG and Standby
Tidal Volume : 50 to 1500 ml
Respiratory Rate : 1 to 60 BPM
Ti : 0.2 to 8.0Sec
I: E Ratio : 4:1 to 1:4
Plateau : 0 to 50
Pressure Support : 5 to 40 cmH2O
Trigger : 0.5 to 5.0 cmH2O
PEEP : 1 to 30 cmH2O
Pressure Limit : 20 to 60 mBar
Backup RR : 6to 60 BPM
Backup Mode : VCMV, V- SIMV, PCMV, P-SIMV and PRVC
Alarms : Low and High for Pressure, RR, Minute Volume and FIO2,
Active patient, Driving Gas failure, low battery indication
Patient Type : Adult and Pediatric
Battery Backup : 2 hours (Lithium-ion
ROTA METER : Five Tube Flow meter Bobbin Type
02 Tube : 0.1L/min-1L/max, 1L/min 10L/max
N20 Tube : 0.1L/min-1L/max, 1L/min 12L/max
Air Tube : 0.1L/min-15L/min 02 and N20 Linkage Device, Hypoxy Guard
Oxygen Flush : 25L/min-75L/min
Gas source pressure
02 : 0.25Mpa-0.65MPa
N20 : 0.25Mpa-0.65MPa
Air : 0.25Mpa-0.65MPa
Gas source pressure
Upgraded integrated Circle Absorber, With twins large volume CO2 absorbing Efficiency With non return respiratory valve and expiratory valve on it avoid gas back flowing With APL valve on it, the airway pressure could be adjusted freely With 'Manual/Ventilation 'Switch On it, easily and quickly change
FRAME
Rust Proof Epoxy Coated High Strength Frame Pipeline Attachment for 02, N20. Air Yokes For Two Each Cylinders of 02 and N20 Select tec bar with provision to mount 2 Vaporizers
Inclusive of all taxes
You Save: 0
Varanasi , India
Service Provider , Manufacturer, Professional Services, Contractor, Retailer, Brand Owner, Distributor, Exporter, Importer, Wholesaler, Startup
GST- 09ckpps7713d1zp