Our Products
Showing 1-7 of 7 products
Cryo 2 (Double Density Gradient Kit) for Semen Processing
Double Density Gradient Media Kit consisting of 1 x 1ml Density Gradient 45%, 1 x 1ml Density Gradient 90% & 1 x 5ml HTF based Wash Media, for Semen Processing in your IUI / IVF / ANDROLOGY laboratory.
The Media is Hepes Modified, hence does not require CO2 Incubation.
The Density Media is made using Silane coated colloidal Silica & the Semen Wash Media is the exact duplication of Human Tubal Fluid, which is naturally found in the fallopian tubes, the natural environment for the sperms.
Density Gradient is the ideal technique for processing Semen, as this technique reduces the handling time, thereby considerably reducing the chances of the damages caused by Free Oxygen Radicals
Cryo's Trinocular Microscope
Cryo’s TRINOCULAR MICROSCOPE
• Make – Alco- Cryocell
• Mechanical Tube Length 160 mm.
• Din objectives 5X, 10X, 20X, 40X & 100X, with anti fungal treatment.
• 450 inclined with 3600 Rota table Trinocular head.
• Camera port ready.(can be connected with a PC / monitor) HDMI Camera option also available
• Co- axial built in Mechanical stage 125 x 150 mm with fine vernier graduation, designed with convenient coaxial adjustment on ball bearing guide ways for smooth slide manipulation through 50 x 70 mm.
• Dust proof Quadruple ball bearing revolving nose piece with positive click stops. Co-axial course & fine focusing adjustment knobs. Fine motion graduated to .002 mm. Sub stage abbe type N.A. 1.25 condenser focusable with rack & pinion, continuously variable iris diaphragm with built in swing out filter
Cryos Semenology Incubator
Cryo’s SEMENOLOGY INCUBATOR
• Make – Cryocell
• Inner Size 12” X 12”
• Double walled, outer chamber made of M.S. duly powder coated, with glass wool insulation between two walls. Inner wall made of Stainless steel.
• Heating elements are placed in the ribs of the bottom & the sides for uniform heating.
• Fitted with air circulating fan for better maintenance of ambient temp. Inside the incubator.
• Air Ventilator, adjustable fitted on the top.
• Provided with ‘L’ shaped thermometer fixed at the front of the incubator.
• The Temperature is controlled by a PID (proportional–integral–derivative controller) with an accuracy of + 0.10 C fitted with the main switch.
• Supplied with perforated shelves & workable on 220 volts 50 Hz AC mains.
• The Incubator is warranted for a period of 12 months from the date of Invoicing for any manufacturing defect.
Cryo's Laminar Flow Hood
Cryo’s LAMINAR FLOW HOOD
• Make Cryocell Size 2.5’ X 2’ X 2’ Workspace 2.5’ X 2’
• Manufactured as per US Federal standards to retain particles up to 0.3 microns (micrometer) using HEPA filters (non woven fiber glass pleated paper).
• Filtering efficiency: 99.997 % Air Velocity across workspace 90 + 20 feet per minute.
• Full body made of mild steel (powder coated) with Stainless steel work table.
• Easy dis-mantalable construction.
• Illuminated by fluorescent tube lights.
• Fitted with Static pressure indicator (Manometer)
• Inner Chamber sterilization through UV- Germicidal tube.
• The Laminar Flow hood is warranted for a period of 12 months from the date of Invoicing for any manufacturing defect.
TURNKEY SETUP OF YOUR IUI / ANDROLOGY LABORATORY
We at Cryocell have had the privilege of setting up more than 500 IUI Labs across India & Neighbouring countries.
We have also been Manufacturing IUI Media & IUI disposables in a very user friendly, Ampoulised packing, which does not require expensive CO2 Incubation.
During the Installation of your Lab, We shall be pleased to impart Hands on training to your Staff members in your Hospital free of cost. Please note that you will only have to arrange the semen samples & rest all (Media & Disposables) would be complimentary.
You will take a day or two to get 3 & 4 staff members to get trained/conversant in all the Semen Analysis, Sperm Function Tests and Sperm Processing Techniques required for Intra Uterine Insemination / IVF.
Cryo One - Single Density Gradient Media for Semen Processing
Single Density Gradient Media consisting of 1 x 2 ml Density Gradient Media and 1 x 5ml HTF based wash Media
Used for Semen Processing in your IUI / IVF / ANDROLOGY laboratory. The Media is Hepes Modified, hence does not require CO2 Incubation.
The Density Media is made using Silane coated colloidal Silica & the Semen Wash Media is the exact duplication of Human Tubal Fluid, which is naturally found in the fallopian tubes, the natural environment for the sperms.
Density Gradient is the ideal technique for processing Semen, as this technique reduces the handling time, thereby considerably reducing the chances of the damages caused by Free Oxygen Radicals
Cryocell Sperm Counting Chamber for rapid Semen Analysis
India's First Indigenous Sperm counting Chamber launched in 2001.
• Cryocell Sperm Counting Chamber. 10 micron depth.
• 100 micron X 100 micron grid using the bright Line technology leading to longer lasting grid on the chamber.