Inclusive of all taxes
The Start Up Burner from L J ENERGY SOLUTIONS is an industrial burner designed for combustion and boiler firing duties in demanding process environments. It is specifically positioned for use in recovery boilers and fluidized bed boilers, making it suitable for plants that require dependable ignition and start-up support for complex thermal systems. The product is described as part of the Burners & Combustion Systems range and is aligned with operational needs where controlled firing, fuel flexibility, and application matching are important for procurement and replacement planning. This Start Up Burner is identified for use with natural gas, HFO (heavy fuel oil), and LFO (light fuel oil), giving buyers fuel-selection flexibility depending on the plant’s available utilities and operating strategy. The product information also references gas/electric or HEA ignition, which supports industrial start-up and load conditions where reliable ignition performance is essential. Because the listing is intended for buyer-side verification, it is especially relevant for engineering teams, maintenance departments, and project procurement specialists who need to confirm compatibility with their boiler or combustion system before ordering. From an application standpoint, this burner is suitable for start-up and load burner duties in recovery boilers and fluidized bed boilers. These boiler types typically operate in tough industrial environments, so a burner in this category is generally selected for stable combustion support, process reliability, and continuity of operation. The stated operating details, including combustion air temperature max of +250°C, combustion air pressure loss of 80–120 mmwc, instrument air pressure of 5–7 bar, fuel oil pressure of 12 bar for air/steam atomization, and fuel gas pressure of 6 bar max, provide important reference points for engineering review and fit confirmation. For B2B buyers, this product is best viewed as an industrial combustion component for projects, replacements, shutdown spares, and plant maintenance programs. Before purchase, users should verify the exact configuration, connection details, included scope, and integration requirements with their existing boiler system. The listing supports procurement evaluation where reliability, fuel compatibility, and burner duty alignment are critical to plant operation.
Key Features
| Features | Description |
|---|---|
| Product Type | Start Up Burner |
| Application | Recovery boiler and fluidized bed boiler |
| Fuel Compatibility | Natural gas, HFO, LFO |
| Ignition Type | Gas/electric or HEA |
| Combustion Air Temperature | Max. +250°C |
| Combustion Air Pressure Loss | 80–120 mmwc |
| Instrument Air Pressure | 5–7 bar |
| Fuel Oil Pressure | 12 bar (air/steam atomization) |
| Fuel Gas Pressure | 6 bar max |
| Supply Context | Burners & Combustion Systems range |
| Attributes | Description |
|---|---|
| Product Name | Start Up Burner |
| Store Name | L J ENERGY SOLUTIONS |
| MOQ | 1 |
| Category | Burners & Combustion Systems |
| Application | Recovery Boiler, Fluidized Bed Boiler |
| Fuel | HFO, LFO, Natural Gas |
| Ignition | Gas/electric or HEA |
| Combustion Air Temperature Max | +250°C |
| Combustion Air Pressure Loss | 80–120 mmwc |
| Instrument Air Pressure | 5–7 bar |
| Fuel Oil Pressure | 12 bar (air/steam atom) |
| Fuel Gas Pressure | 6 bar max |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
Yes, the listing specifically states recovery boiler and fluidized bed boiler applications, making it relevant for those industrial boiler systems subject to final fit verification.
The stated fuel options are HFO, LFO, and natural gas, so buyers can verify compatibility with their plant fuel availability and operating mode.
The product text mentions gas/electric or HEA ignition, which should be checked against the existing boiler control and start-up arrangement.
The listing specifies combustion air pressure loss of 80–120 mmwc, instrument air pressure of 5–7 bar, fuel oil pressure of 12 bar for air/steam atomization, and fuel gas pressure of 6 bar max.
It may be suitable for replacement use, but buyers should confirm mounting arrangement, interface details, included scope, and duty conditions before standardizing it for retrofit or spare parts planning.
Brand: lj energy
Country Of Origin: India
Start-up burners provide reliable auxiliary firing during boiler commissioning and low-load operation. They support multiple fuels and are used to bring large boilers to ignition safely and predictably.
Start-up burners are essential for recovery boilers, fluidized bed boilers, and large packaged boilers to enable controlled warm-up and stabilization. They are engineered to operate at low fire with pilot and automatic ignition systems for safety.
Provide boiler type, required startup duty, and fuel options to receive a startup burner proposal and commissioning plan.