Inclusive of all taxes
The MACRO SCIENTIFIC WORKS PVT LTD HORIZONTAL CYLINDRICAL AUTOCLAVE MSW-103(FAD) is a double-walled, horizontal autoclave designed specifically for critical sterilization applications demanding absolute reliability in eliminating all viable microorganisms. Featuring a robust construction with both the inner sterilizing chamber and outer walls fabricated from premium stainless steel (SS-304), this autoclave ensures unmatched durability and corrosion resistance. Its external boiler operates at a pressure of 1.2 kgf/cm² (15 psi) at 121°C to deliver consistent and efficient steam sterilization. The inner chamber size of 400 mm diameter by 600 mm height offers an 88-liter capacity suitable for hospital, pharmaceutical, and research laboratory settings. Powered by a 6.0 KW industrial-grade energy-efficient heater, the unit significantly reduces power consumption while ensuring rapid steam generation. The autoclave includes a microprocessor-based fully automatic fuzzy logic control system with timer and buzzer, providing precise control over the sterilization cycle for optimal results. Safety features such as automatic vacuum breaker, low water level cut-off, and solenoid valve for automatic purging and exhaust add layers of operational safety. Its heavy-duty stainless steel lid and the separate boiler system facilitate easy maintenance and ensure long-term, trouble-free performance. This autoclave is ideal for institutions and industries requiring stringent microbial destruction and reliable sterilization.
Key Features
| Features | Description |
|---|---|
| Model | HCA-88(FAD) |
| Inner Chamber Material | Stainless Steel SS-304 |
| Outer Wall Material | Stainless Steel SS-304 |
| Boiler Type | External Boiler, Stainless Steel SS-304 |
| Inner Chamber Dimensions | Diameter 400 mm x Height 600 mm |
| Capacity | 88 Liters |
| Heater Load | 6.0 KW Industrial Grade Energy-Efficient |
| Control System | Microprocessor Based Fully Automatic Fuzzy Logic Controller with Timer and Buzzer |
| Operating Pressure | 0-2.1 kgf/cm² (30 psi) |
| Safety Features | Automatic Vacuum Breaker, Low Water Level Cut-Off, Solenoid Valve for Automatic Purging and Exhaust |
| Lid Material | Thick Machined Stainless Steel Plate |
| Additional Features | Separate Steam Injection and Exhaust Valves, Double Walled Chamber, No Steam Jacket Included |
| Attributes | Description |
|---|---|
| Model Number | HCA-88(FAD) |
| Inner Dimensions (Dia x Height) | 400×600 mm |
| Capacity | 88 Liters |
| Heater Load | 6.0 KW |
| Control System | PLC-based Microprocessor with Fuzzy Logic Control |
| Material of Sterilizing Chamber | SS-304 Stainless Steel |
| Material of Steam Jacket | SS-304 Stainless Steel (Double Walled Chamber but No Jacket Supplied) |
| Material of External Wall | SS-304 Stainless Steel |
| Boiler Pressure Rating | 1.2 kgf/cm² (15 psi) at 121°C |
| Operating Pressure | 0-2.1 kgf/cm² (30 psi) |
| Safety Features | Automatic Vacuum Breaker, Low Water Level Cut-Off Device, Solenoid Valve for Automatic Purging and Exhaust |
| Power Supply | 6.0 KW Heater |
| Lid Material | Thick Machined Stainless Steel Plate |
| Automation Level | Fully Automatic |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
The MSW-103(FAD) features a microprocessor-based fully automatic fuzzy logic control system with a timer and buzzer for precise cycle management.
No, the MSW-103(FAD) model has a double walled chamber with an external boiler but is supplied without a steam jacket.
Safety features include an automatic vacuum breaker to prevent vacuum formation, an automatic low water level cut-off for element protection, and solenoid valves for automatic purging and exhaust.
Both the sterilizing chamber and external walls are made of high-quality SS-304 stainless steel, providing excellent corrosion resistance and durability.
The boiler is rated at 1.2 kgf/cm² (15 psi) at 121°C with an operating pressure range of 0-2.1 kgf/cm² (30 psi).
Brand: mac
Country Of Origin: India
“MAC” Horizontal Double Walled Autoclaves are most ideal for critical applications requiring assured and reliable total destruction of all living micro-organisms. Both inner chamber and outer wall made of S.S.
MODEL : #HCA-88(FAD)
Inner Dimensions (Dia x Height) : 400×600mm
Capacity : 88 ltrs
Heater Load : 6.0 KW
Controller (PLC Based) : Microprocessor based Fully Automatic Fuzzy Logic Control system with timer buzzer
MOC (Sterilizing Chamber) : Stainless Steel (SS-304)
MOC (Steam Jacket) : Stainless Steel (SS-304).
MOC (External Wall) : Stainless Steel (SS-304)
MOC (Boiler): 1.2 kgf /cm² (15 psi) at 121°C
Operating parameters : 0-2.1 kgf /cm² (30 psi)
For units fitted with S.S. Boiler, separate valves for injecting the steam into the main chamber and releasing the steam in atmosphere after use are provided.
Automatic vacuum breaker is provided to break the vacuum in case of formation of vacuum due to steam condensation.
Automatic Low Water Level Cut-Off Device fitted for general safety of the element.
Lid is made of thick machined stainless steel plate.
Solenoid Valve for automatic purging and exhaust (user settable).
Supplied without jacket (Double walled chamber but with separate boiler).
Industrial grade energy efficient heaters reduce power bills drastically.
Inclusive of all taxes
You Save: 0
Delhi , India
Manufacturer, Brand Owner, Exporter
GST- 07aafcm2231f1zw