• Key Features & Attributes
  • Ratings & Reviews
  • Know your Supplier
  • Product description from supplier

Benchtop Multiparameter Meter

Inclusive of all taxes

Benchtop Multiparameter Water Quality Meter


High-precision multiparameter water quality meter contains measurement modes for pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and dissolved oxygen, the setup menu offers 17 optional settings for customization.

pH Mode:

• Multiparameter water quality meter is equipped with a large backlit LCD display.

• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.

• Automatic electrode diagnosis shows the pH slope and zero offset.

ORP Mode:

• 1 point offset calibration allows adjusting the displayed value to a known standard.

• Relative and absolute millivolt modes ensure the reliable ORP measurements.

Ion Concentration Mode:

• 2 to 5 points calibration, including the selection of 8 concentration points.

• Automatic electrode diagnosis shows the calibration points and slopes.

• Direct ion concentration readout simplifies the measurement process.

• Selectable concentration units (ppm, mg/L, mol/L) and ionic valency.

Conductivity/TDS/Salinity/Resistivity Modes:

• 1 to 5 points calibration with automatic recognition for conductivity standards.

• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and

  pure water compensations, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:

• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.

• Salinity and barometric pressure compensations eliminate the measurement errors.

Other Features:

• Automatic temperature compensation ensures accurate readings over the entire range.

• Auto-read function senses and locks the measurement endpoint.

• Calibration due alarm reminds the user to calibrate the meter regularly.

• Setup menu allows setting the number of calibration points, stability criteria, temperature unit,

  date and time, auto-power off, etc.

• Reset function automatically resumes all settings back to the factory defaults.

• Expanded memory stores or recalls up to 500 data sets.

• USB communication interface for data transfer and timed interval readings.



pH Range: -2.000~20.000pH

Accuracy: ±0.002pH

Resolution: 0.1, 0.01, 0.001pH, Selectable

Calibration Points: 1 to 5 points

Calibration Solutions: USA, NIST, DIN or User-defined

Temperature Compensation: 0~100°C, 32~212°F

Compensation Mode: Manual or Automatic


mV  Range: -1999.9~1999.9mV

Accuracy: ±0.2mV

Resolution: 0.1, 1mV, Selectable

Calibration Points: 1 point (Only for Relative mV mode)

Calibration Range: ±200mV


Ion  Range: 0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE)

Accuracy: ±0.5% F.S (Monovalent), ±1% F.S (Divalent)

Resolution: 0.001, 0.01, 0.1, 1

Calibration Points: 2 to 5 points

Calibration Solutions: 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L

Temperature Compensation: 0~100°C, 32~212°F

Compensation Mode: Manual or Automatic


Conductivity  Range: 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm

Accuracy: ±0.5% F.S

Calibration Points: 1 to 5 points

Calibration Solutions: 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm

Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic

Temperature Coefficient: 0.0~10.0%/°C

Compensation Modes: Linear or Pure Water

Cell Constant: K=0.1, 1, 10 or User-defined

Normalization Temperature: 20°C or 25°C


TDS  Range: 0~100ppt (Max. 200ppt, depending on factor setting)

Accuracy: ±1% F.S

TDS Factor: 0.1~1.0 (Default 0.5)

Salinity  Range: 0~10ppt (Max. 80ppt)

Accuracy: ±1% F.S

Measurement Modes: Seawater or Practical Salinity


Resistivity  Range: 0~100MΩ

Accuracy: ±1% F.S

Resolution: 0.01, 0.1, 1


Dissolved Oxygen  Range: 0.00~20.00mg/L (or ppm)

Accuracy: ±0.2mg/L

Resolution: 0.01mg/L

Calibration Points: 1 or 2 points

Temperature Compensation: 0~50°C, 32~122°F, Automatic

Pressure Correction: 60.0~112.5kPa, 450~850mmHg

Salinity Correction: 0~50g/L


% Saturation of Oxygen  Range: 0.0~200.0%

Accuracy: ±2.0%

Resolution: 0.1, 1%


Temperature  Range: 0~105°C, 32~221°F

Accuracy: ±0.5°C, ±0.9°F

Resolution: 0.1°C

Calibration Points: 1 point

Calibration Range Measured value: ±10°C


Others  Features:

  • Hold Function Manual or Automatic endpoint detection
  • Stability Conditions Low or High
  • Calibration Due 0 to 31 days
  • Power Off Manual or Automatic (10, 20, 30 minutes)
  • Reset Function Yes
  • Memory Stores up to 500 data sets
  • Output USB Communication Interface
  • Connector BNC, 6-pin Mini Plug
  • Display LCD (130×110mm)
  • Power Requirements DC5V, using AC adapter, 220VAC/50Hz
  • Dimensions 210(L)×188(W)×60(H)mm
  • Weight 1.5kg

Be the first to write a review

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Benchtop Multiparameter Water Quality Meter


High-precision multiparameter water quality meter contains measurement modes for pH, ORP, ion concentration, conductivity, TDS, salinity, resistivity and dissolved oxygen, the setup menu offers 17 optional settings for customization.

pH Mode:

• Multiparameter water quality meter is equipped with a large backlit LCD display.

• 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.

• Automatic electrode diagnosis shows the pH slope and zero offset.

ORP Mode:

• 1 point offset calibration allows adjusting the displayed value to a known standard.

• Relative and absolute millivolt modes ensure the reliable ORP measurements.

Ion Concentration Mode:

• 2 to 5 points calibration, including the selection of 8 concentration points.

• Automatic electrode diagnosis shows the calibration points and slopes.

• Direct ion concentration readout simplifies the measurement process.

• Selectable concentration units (ppm, mg/L, mol/L) and ionic valency.

Conductivity/TDS/Salinity/Resistivity Modes:

• 1 to 5 points calibration with automatic recognition for conductivity standards.

• Selectable cell constant (K=0.1/1/10), reference temperature (20/25°C), TDS factor, linear and

  pure water compensations, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:

• 1 or 2 points calibration using the air-saturated water or zero oxygen solution.

• Salinity and barometric pressure compensations eliminate the measurement errors.

Other Features:

• Automatic temperature compensation ensures accurate readings over the entire range.

• Auto-read function senses and locks the measurement endpoint.

• Calibration due alarm reminds the user to calibrate the meter regularly.

• Setup menu allows setting the number of calibration points, stability criteria, temperature unit,

  date and time, auto-power off, etc.

• Reset function automatically resumes all settings back to the factory defaults.

• Expanded memory stores or recalls up to 500 data sets.

• USB communication interface for data transfer and timed interval readings.

pH Range: -2.000~20.000pH

Accuracy: ±0.002pH

Resolution: 0.1, 0.01, 0.001pH, Selectable

Calibration Points: 1 to 5 points

Calibration Solutions: USA, NIST, DIN or User-defined

Temperature Compensation: 0~100°C, 32~212°F

Compensation Mode: Manual or Automatic


mV  Range: -1999.9~1999.9mV

Accuracy: ±0.2mV

Resolution: 0.1, 1mV, Selectable

Calibration Points: 1 point (Only for Relative mV mode)

Calibration Range: ±200mV


Ion  Range: 0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE)

Accuracy: ±0.5% F.S (Monovalent), ±1% F.S (Divalent)

Resolution: 0.001, 0.01, 0.1, 1

Calibration Points: 2 to 5 points

Calibration Solutions: 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L

Temperature Compensation: 0~100°C, 32~212°F

Compensation Mode: Manual or Automatic


Conductivity  Range: 0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm

Accuracy: ±0.5% F.S

Calibration Points: 1 to 5 points

Calibration Solutions: 10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm

Temperature Compensation: 0~100°C, 32~212°F, Manual or Automatic

Temperature Coefficient: 0.0~10.0%/°C

Compensation Modes: Linear or Pure Water

Cell Constant: K=0.1, 1, 10 or User-defined

Normalization Temperature: 20°C or 25°C


TDS  Range: 0~100ppt (Max. 200ppt, depending on factor setting)

Accuracy: ±1% F.S

TDS Factor: 0.1~1.0 (Default 0.5)

Salinity  Range: 0~10ppt (Max. 80ppt)

Accuracy: ±1% F.S

Measurement Modes: Seawater or Practical Salinity


Resistivity  Range: 0~100MΩ

Accuracy: ±1% F.S

Resolution: 0.01, 0.1, 1


Dissolved Oxygen  Range: 0.00~20.00mg/L (or ppm)

Accuracy: ±0.2mg/L

Resolution: 0.01mg/L

Calibration Points: 1 or 2 points

Temperature Compensation: 0~50°C, 32~122°F, Automatic

Pressure Correction: 60.0~112.5kPa, 450~850mmHg

Salinity Correction: 0~50g/L


% Saturation of Oxygen  Range: 0.0~200.0%

Accuracy: ±2.0%

Resolution: 0.1, 1%


Temperature  Range: 0~105°C, 32~221°F

Accuracy: ±0.5°C, ±0.9°F

Resolution: 0.1°C

Calibration Points: 1 point

Calibration Range Measured value: ±10°C


Others  Features:

  • Hold Function Manual or Automatic endpoint detection
  • Stability Conditions Low or High
  • Calibration Due 0 to 31 days
  • Power Off Manual or Automatic (10, 20, 30 minutes)
  • Reset Function Yes
  • Memory Stores up to 500 data sets
  • Output USB Communication Interface
  • Connector BNC, 6-pin Mini Plug
  • Display LCD (130×110mm)
  • Power Requirements DC5V, using AC adapter, 220VAC/50Hz
  • Dimensions 210(L)×188(W)×60(H)mm
  • Weight 1.5kg


Benchtop Multiparameter Meter

Inclusive of all taxes

You Save: 0

Send Inquiry
HAICO INDIA

Mumbai , India

Service Provider , Service Center, Manufacturer, Professional Services, Contractor, Retailer, Brand Owner, Distributor, Exporter, Importer, Wholesaler

  • Secure
    Transaction

  • Free
    Delivery

  • Day
    Dispatch

Report a problem with this product