Mobile SAR Testing Laboratory Services for Handset Compliance
Sold by bharat test house private limited · Service Provider , Professional Services, Brand Owner · Sonipat, Haryana, India
Sold by bharat test house private limited · Service Provider , Professional Services, Brand Owner · Sonipat, Haryana, India
Importers · Distributors · Wholesalers
bharat test house private limited is a Service Provider , Professional Services, Brand Owner based in Sonipat Haryana India.
Service Provider , Professional Services, Brand Owner · Sonipat, Haryana, India
Bharat Test House Pvt. Ltd. (BTH) is a trusted and time-tested independent testing, inspection and certification organization serving leading manufacturers, exporters, importers, government and non-government institutions across India and international markets. With strong technical expertise and accredited facilities, BTH provides reliable, accurate and prompt services in the areas of testing, inspection, certification, calibration and consultancy for a wide range of industrial products and materials. BTH is committed to supporting quality, safety and global compliance by helping industries meet National and International Standards. The organization continuously works towards educating and motivating manufacturers, suppliers and users for procurement and supply of quality products conforming to regulatory and customer-specific requirements. With a customer-focused approach, technical competence and commitment to integrity, BTH has emerged as a dependable partner for industries seeking trusted quality assurance and export compliance solutions.
Registered address: Sonipat, India. Industry: Business Services & Consultancy > Process & Certification.
Mobile SAR Testing for Handsets and Wireless Devices Mobile SAR testing measures radiofrequency energy absorption from handsets and wearable wireless devices to ensure compliance with human exposure limits. The laboratory service provides test setups and measurement procedures that quantify Specific Absorption Rate (SAR) under representative usage conditions for procurement and certification workflows. Testing & Calibration Capability Overview Applicable standards and measurement protocols for SAR assessment. Measurement equipment: SAR phantom models, probe systems and network analyzers. Test conditions: body-worn and head models across multiple frequency bands. Reporting: measured SAR values, scan maps and compliance verdicts aligned to applicable exposure limits. Sample handling: device firmware state, power control and positioning logs are recorded. Engagement Terms & Scheduling Service Format: In-lab SAR measurement with pre-test setup verification and firmware control. Turnaround Time: Typically 7–10 working days for full-band SAR suites; multi-band or repeat testing may require longer. Sample Requirement: Multiple production samples or engineering prototypes per measurement campaign. Pricing Basis: Pricing per campaign driven by number of frequency bands and positioning variants. Quality Assurance: Measurement uncertainty and calibration records accompany final reports.
Certification teams, QA managers and regulatory officers use SAR testing to demonstrate compliance with exposure limits prior to market launch. The service resolves exposure uncertainty by providing measured SAR values under defined user scenarios, supporting product labeling and regulatory submissions. Applications include handset type approval, wearable device evaluation, and vendor qualification for wireless products.
The SAR measurement workflow uses anthropomorphic phantoms with tissue-simulating liquids, calibrated probe systems, and networked signal sources. Instrumentation includes calibrated SAR probes, robotic positioning systems, and spectrum/network analyzers. Methods reference recognized measurement protocols to ensure repeatable positioning, power control, and data capture for each band and usage posture.
Buyers should confirm target frequency bands, intended use postures (handheld, body-worn), and firmware test modes before booking. Early alignment on reference power levels and production sample availability reduces repeat test cycles. If SAR values approach limits, plan for design mitigation or additional shielding validation.
Share device type, frequency bands, and sample quantity to receive a SAR test scope, schedule, and estimate.
| S. No. | Testing Product Category | Related Standard |
|---|---|---|
| 1 | Testing of Devices Used in Close Proximity to Head & Body | IEEE 1528, IEC/EN 62209-1, IEC/EN 62209-2, EN 50360, IEC 62479 |
Description provided by bharat test house private limited.
| Product Title | Mobiles SAR(Specific Absorption Rate) |
|---|---|
| Store Name | BHARAT TEST HOUSE PRIVATE LIMITED |
| Product Category | consumer electronics > mobile phone and accessories > mobile phones |
| Product Type | Service |
| Minimum Order Quantity | 1 |
| Service Scope | RF exposure / SAR measurement |
| Test Object | Wireless products and mobile handsets |
| Applicable Technologies | Wi-Fi, Bluetooth, ZigBee, RFID, GSM 2G, UMTS 3G, LTE |
| Frequency Bands | 800 MHz, 900 MHz, 1800 MHz, 2100 MHz |
| Measurement Unit | W/kg |
| Test Procedure Basis | IEEE standard based test procedure |
| Standards | IEC 62209-1, IEC 62209-2 |
| Additional Standards Mentioned | IEEE 1528, IEC/EN 62209-1, IEC/EN 62209-2, EN 50360, IEC 62479 |
| US Regulatory Reference | 47 CFR Part 2, section 2.1093 |
| US SAR Limit | 1.6 mW/g averaged over 1 gram of tissue |
| US Extremity SAR Limit | 4 mW/g averaged over 10 grams for hands, wrists, feet and ankles |
| EU Regulatory Reference | Council Recommendation 1999/519/EC |
| Test Simulation | Human head or body phantom |
| Tested Use Case | Devices operating within 20 cm from the body |
| Compliance Support | Product qualification, certification support, regulatory filing support |
| Category | SAR Testing Services |
|---|---|
| Primary application | Wholesale, distribution, and international sourcing |
| Brand | bth |
| Product type | Service |
| Lead time | On request |
|---|---|
| Packaging | As per buyer requirement |
| Storage condition | As recommended by supplier |
| Origin | India |
| Form | As listed by supplier |
| Minimum order | 1 unit |
|---|---|
| Lead time | On request |
| Payment terms | As per negotiated commercial agreement. |