Formalin Tablet 1 gm is specifically formulated for use in Formalin Chambers to provide effective sterilization and disinfection of medical instruments and small articles that cannot undergo autoclaving. Ideal for sterilizing stainless steel catheters, rubber, plastic, and polymask articles including syringes, needles, small scissors, knives, bronchoscopes, systoscopes, and uretic catheters. Additionally, these tablets are recommended for sterilizing wooden tongue spatulas, Reuban valves, and similar items. The tablets contain paraformaldehyde which delivers broad-spectrum antimicrobial action, making them highly effective against bacteria when used with appropriate exposure times and conditions. For bacterial population reduction, 1 tablet per dm3 is used with a minimum exposure of 3 hours. For complete sterilization, 10 tablets per dm3 are required with a minimum exposure of 5 hours. Cold sterilization, a last-resort option for items unsuitable for other sterilization methods, requires 10 tablets per dm3 and exposure of 15-24 hours. It is essential that the sterilization container maintains a tight seal and achieves around 80% relative air humidity to ensure effectiveness. The product comes in hygienic packaging, available in quantities of 50, 100, 250, 500, or 1000 tablets per container with customization options to meet specific customer requirements. WHO-GMP certified, this formalin tablet offers a balanced composition providing stability and consistent sterilization results, making it an indispensable sterilization agent in medical, dental, and laboratory settings.

Key Features

Features Description
Certification WHO-GMP Certified
Tablet Weight 1 gram per tablet
Application Sterilization of medical instruments and small articles in formalin chambers
Effectiveness Broad-spectrum antimicrobial action against bacteria
Packaging Available in 50, 100, 250, 500, 1000 tablets per container; customizable packing sizes
Usage Condition Requires tight containers with 80% relative humidity for effectiveness
Minimum Exposure Time 3 hours for bacterial reduction with 1 tablet/dm3, 5 hours for sterilization with 10 tablets/dm3
Cold Sterilization 15 to 24 hours exposure with 10 tablets/dm3, used only when other methods are unsuitable
Hygienic Packing Ensures product stability and safety
Balanced Composition Ensures consistent efficacy and stability
Attributes Description
Chemical Composition Paraformaldehyde
Form Tablet
Tablet Weight 1 gm
Usage Environment Formalin chambers, sealed instrument cabinets, catheter boxes, plastic bags
Relative Humidity Needed Approximately 80%
Sterilization Capacity 1 tablet per dm3 for bacterial reduction, 10 tablets per dm3 for sterilization
Exposure Time Minimum 3 hours for bacterial reduction, minimum 5 hours for sterilization, 15-24 hours for cold sterilization
Packing Options 50, 100, 250, 500, 1000 tablets per container; customizable
Shelf Life Stable under hygienic packing (specific shelf life to be confirmed by manufacturer)
Intended Use Sterilization of medical and dental instruments not suitable for autoclaving

*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.

Be the first to write a review

Effective sterilization requires 10 tablets per dm3 with a minimum exposure time of 5 hours under conditions of approximately 80% relative humidity.

Yes, cold sterilization can be performed using 10 tablets per dm3 with an exposure time ranging between 15 to 24 hours. This method should be used only when other sterilization methods are unsuitable.

It is suitable for sterilizing stainless steel catheters, syringes, needles, small scissors, bronchoscopes, uretic catheters, and other small articles including wooden tongue spatulas and Reuban valves that cannot be autoclaved.

Formal tablets are available in containers of 50, 100, 250, 500, and 1000 tablets and packaging sizes can be customized as per customer requirements.

The tablets must be used in tightly sealed containers with an approximate relative air humidity of 80% to ensure their sterilization effectiveness.

  • Incorporation Type

  • GST

  • GST Registration Date

  • Number of Employees

  • Import Export Code (IEC)

  • Year of Establishment

  • Nature of Business

  • GlobalLinker Member Since

Country Of Origin: India

Formalin Tablet 1 gm

Description:

Mainly for use in Formalin Chambers. For sterilization of S.S. Catheters, Rubber/Plastic/Polymasks Articles, Syringes, Needles, Small Scissors, Knives, Bronchoscopes, and Systoscope & Systoscopy Instruments including Uretic Catheters. These can also be used to sterilize Wooden Tongue Spatulas, Reuban Valves and all other small articles that cannot be autoclaved.

Formalin Tablets / Paraformaldehyde Tablets are very effective against a wide spectrum of organisms. They may be recommended for targeted de germing measures in medical practice. Formalin Tablets /Paraformaldehyde Tablets are well suited for the reduction of the bacterial population and the storage of non-wrapped sterilized instruments. For this purpose, 1 tablet/dm3 is needed. The exposure time required for bacterial count reduction is no less than 3 hours. Despite certain limitations, Tablets may be used for disinfecting.

Instructions for use:

The tablets should be employed only in containers that are as tight fitting as possible (preferentially instrument cabinets, Heinemann cabinets, catheter boxes and plastic bags). The minimum period of exposure is 5 hours, and 10 tablets / dm3 are necessary. Cold sterilization requires 10 tablets / dm3, too, but the exposure time ranges from 15 to 24 hours. This method (which must be considered an expedient) should be employed only if the respective device or instrument cannot be sterilized by other techniques. In any case, 80% relative air humidity is a must in the devices in which Formalin Tablets / Paraformaldehyde Tablets are used. The objects to be disinfected should be neither too contaminated nor too soiled.

Packing Details:

50/100/250/500/1000 Tablets Containers.

The size of the container and number of tablets in a container can be modified as per customer’s specification.

Key Feature:

WHO-GMP Certified

Packaging can be customize

Hygienically packed

Balanced composition

Stability

Highly effective

Cardiovascular Drugs And Medication

Anticoagulants Drugs

Formalin Tablet 1 Gm

Paraformaldehyde Tablet Sterilization

Medical Instrument Sterilizer Tablets

Formalin Chamber Sterilization

Sterilization Tablets For Catheters

WHO-GMP Formalin Tablets

Cold Sterilization Tablet

Medical Sterilization Chemical Tablet

Formalin Tablet 1 gm

Inclusive of all taxes

You Save: 0

Send Inquiry
facmed pharmaceuticals pvt ltd

New Delhi , India

Manufacturer, Professional Services, Contractor, Distributor, Exporter, Importer, Wholesaler

  • Secure
    Transaction

  • Day
    Dispatch

Report a problem with this product