The Eco Spinal Cage is a biocompatible titanium spinal implant meticulously engineered to restore disc height, enhance spinal stability, and promote robust interbody fusion in spinal reconstruction surgeries. Crafted with a hollow mesh design, this cage facilitates optimal packing of bone graft materials, significantly improving osteointegration and fusion outcomes. Its high-precision anatomical shaping ensures a secure fit tailored to patients' spinal anatomy, while radiographic markers aid precise intraoperative placement. The implant’s anti-subsidence textured surfaces prevent sinking into vertebral endplates, preserving alignment and stability post-surgery. Available in multiple diameters, lengths, and lordotic angles, the Eco Spinal Cage caters to diverse clinical indications such as degenerative disc disease, spondylolisthesis, trauma-induced instability, and revision spinal surgeries. With superior load-bearing capacity and biocompatible titanium construction, the Eco Spinal Cage delivers long-term durability, making it an invaluable tool for spine surgeons seeking reliable spinal fusion solutions that restore spinal structure and functional integrity.
Key Features
| Features | Description |
|---|---|
| Material | High-grade titanium for strength and biocompatibility |
| Design | Hollow mesh architecture allowing bone graft packing |
| Disc Height Restoration | Effectively restores spinal disc height to relieve nerve compression |
| Size Options | Multiple diameters, lengths, and lordotic angles for anatomical precision |
| Fusion Surface | Textured and porous surfaces enhance bone integration |
| Radiographic Markers | Facilitates accurate intraoperative positioning |
| Load-bearing Capacity | Supports spinal load in degenerative and traumatic cases |
| Anti-subsidence Features | Prevents implant sinking into vertebral endplates |
| Clinical Applications | Suitable for degenerative disc disease, spondylolisthesis, trauma instability, revision surgeries |
| Attributes | Description |
|---|---|
| Material Composition | Titanium |
| Construction | Hollow/Mesh design with large internal cavity |
| Surface Texture | Textured and porous for enhanced fusion |
| Available Sizes | Various diameters and lengths; multiple lordotic angles |
| Radiographic Features | Integrated radiopaque markers |
| Load Capacity | High load-bearing suitable for spinal stabilization |
| Intended Use | Interbody fusion implant for spinal reconstruction |
| Compatibility | Compatible with bone graft materials |
| Primary Indications | Degenerative disc disease, spondylolisthesis, trauma, revision surgeries |
*Disclaimer: The above description has been AI-generated and has not been audited or verified for accuracy. It is recommended to verify product details independently before making any purchasing decisions.
The hollow mesh design allows generous packing of bone graft material within the cage, which promotes superior osteointegration and fusion strength by facilitating bone growth through and around the implant.
The Eco Spinal Cage incorporates anti-subsidence textured surfaces that increase frictional resistance with vertebral endplates and distribute load evenly to prevent sinking or subsidence post-implantation.
Yes, the Eco Spinal Cage is offered in multiple diameters, lengths, and lordotic angles to accommodate patient-specific anatomical requirements and restore natural spinal alignment.
This implant is suitable for conditions such as degenerative disc disease, spondylolisthesis, spine trauma causing instability, and is also effective in revision spinal fusion surgeries.
Yes, it has integrated radiopaque markers that allow surgeons to verify and adjust the implant’s position accurately during surgery using imaging techniques.
Country Of Origin: India
Titanium Construction: Ensures high strength, biocompatibility, and long-term durability.
Hollow / Mesh Design: Allows packing of bone graft material to promote superior fusion.
Restores Disc Height: Helps relieve nerve compression and improves spinal alignment.
Multiple Size Options: Available in various diameters and lengths for anatomical precision.
Excellent Load-bearing Capacity: Provides stable support in degenerative and traumatic cases.
Enhanced Fusion Surface: Textured or porous surfaces improve bone integration.
The Eco Spinal Cage is a high-precision titanium interbody fusion implant designed to restore disc height, stabilize the spine, and promote strong, long-term bone fusion. Its optimized anatomical shape ensures a secure fit, while the large internal chamber allows generous bone graft placement for enhanced osteointegration. The cage features radiographic markers for accurate intraoperative positioning and anti-subsidence surfaces that help prevent sinking into the vertebral endplates. Available in multiple sizes and lordotic angles, it is suitable for various spinal fusion indications, including degenerative disc disease, spondylolisthesis, trauma-related instability, and revision surgeries. Engineered for durability and reliable fusion outcomes, the Eco Spinal Cage provides surgeons with a dependable solution for restoring spinal alignment and long-term stability.